Human HbA1c(Glycated Hemoglobin A1c) ELISA Kit – 96 tests

Ref.: BL-RE-1000570Manufacturer ref.: ELK11998-96T 96 tests
€625.00 excl. VAT

Human HbA1c(Glycated Hemoglobin A1c) ELISA Kit, 96 tests. For research use only.

Format
96 tests (1 plate of 96 wells)
Species
Human
Target
HbA1c (Glycated Hemoglobin A1c)
Type of dosage
ELISA sandwich
Sensitivity
0.032 µg/mL
Brand
ELK Biotechnology

Quantitative strength ELISA Human HbA1c sandwich (plasma), result in 3.5 h.

This ELISA ELK Biotechnology kit allows quantitative in vitro assays of human HbA1c (Glycated Hemoglobin A1c) in the following samples: plasma.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of HbA1c. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 0.032 µg/mL.

Range of dosage

The range of the assays is 0.16 to 10 µg/mL (highest standard 10 µg/mL).

Samples

Plasma.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, specific antibodies of human HbA1c.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format96 tests (1 plate of 96 wells)
SpeciesHuman
TargetHbA1c (Glycated Hemoglobin A1c)
Type of dosageELISA sandwich
Performance
Sensitivity0.032 µg/mL
Range of dosage0.16 – 10 µg/mL
Standard (maximum concentration)10 µg/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesPlasma
Alternative namesGlycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)10.00 µg/mL : DO 3.068; 5.00 µg/mL : DO 1.725; 2.50 µg/mL : DO 0.976; 1.25 µg/mL : DO 0.551; 0.63 µg/mL : DO 0.332; 0.32 µg/mL : DO 0.169; 0.16 µg/mL : DO 0.090; 0.00 µg/mL : DO 0.060
Recovery (doped samples)serum (n=5): 87-95% (mean 91%); EDTA plasma (n=5): 85-95% (mean 90%); heparin plasma (n=5): 84-92% (mean 88%)
Linearity (dilutions)serum (n=5): 1:2 94-101%, 1:4 83-92%, 1:8 79-92%, 1:16 86-95%; EDTA plasma (n=5): 1:2 81-91%, 1:4 83-95%, 1:8 77-90%, 1:16 77-90%; heparin plasma (n=5): 1:2 88-94%, 1:4 94-107%, 1:8 85-94%, 1:16 96-102%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK11998-96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 120 μL (storage 4°C or -20°C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 12 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?