The polyacrylamide Thermo Scientific™ Pierce desalage columns are ready-to-use, disposable gel filter columns for the separation of proteins and other macromolecules from buffer and molecules.
Polyacrylamide Thermo Scientific™ Pierce desalination columns are ready-to-use, disposable gel filter columns for the separation of proteins and other macromolecules from buffer salts and low molecular weight reagents.
The polyacrylamide desalination columns are pre-filled with porous polyacrylamide microbeads with a molecular weight of 2 K or MWCO as the molecular weight limit of 6/7 K. The three pre-filled column sizes are suitable for processing samples from 30 μl to 2.5 ml. The large columns are intended for desalination of biological samples by gravitational flow. Small centrifugal columns (only 7 K MWCO) are used with a microcentrifuge. Unlike gel filtration resins based on dextran, cellulose and other polysaccharides, polyacrylamide microbead resin is not subject to enzymatic degradation and will not serve as a nutrient medium for bacterial growth. This resin is highly hydrophilic and this property minimizes the possibility of non-specific bonds and problematic interactions with common aqueous components of the samples. Oxidizing agents and hydrazides can be treated without chemical interaction with the substrate. Resin is, however, likely to hydrolyse the amide groups when heated under extreme pH conditions. The resin can be autoclaved under conditions close to neutrality.
Key points: Formats: 5 ml and 10 ml pre-conditioned (MWCO 1.8 K and 6 K only) gravity flow columns and 0.7 ml microcentrifugation columns (MWCO 7 K only) Resin type: porous, Microbeads of polyacrylamide Microbead size: 90 to 180 μm in diameter (resins 6 K and 7 K); 45 to 90 μm in diameter (resin 1.8 K) Flow rate: up to 2.5 ml/min (fast compared to other desalination resins) Chemical stability: water-compatible, saline solutions, Many organic solvents and alkaline or acid conditions Mechanical stability: average rigidity compared to other gel filtration resins Thermal stability: resin can be autoclaved dry or in a solution at neutral pH for 30 minutes at 120°C, without affecting its chromatographic properties.
Resin with molecular retention threshold...
Resin with a 1.8 K molecule retention threshold (only 5 ml column) recovers all peptides and proteins above 1.800 daltons with high efficiency; salts and very small compounds (less than 100 MW) are the only ones to be completely eliminated.
Resin with molecular retention threshold...
Resin with a 6 K molecule retention threshold (only 5 ml and 10 ml columns) recovers proteins above 6,000 daltons with high efficiency; salts and small compounds (less than 1,000 MW) are completely eliminated.
Resin with molecular retention threshold...
The 7 K molecule retention threshold resin (a 0.7 ml centrifugation column only) recovers proteins above 7.000 daltons with high efficiency; salts and small compounds (less than 1.000 MW) are completely eliminated.
Technical specifications
| General |
| Brand | Thermo Scientific |
| Supplier ref. (Fisher Scientific) | 11859350 |
| Specifications |
| Product type | Desalination column |
| Format | Gravity flow column |
| Purification target | Buffer exchange protein |
| Column type | Steric exclusion, polyacrylamide resin |
| MWCO | 6.0 kDa |
| Disposable | Yes |
| Quantity | 5 columns |
| Physical characteristics |
| Volume (metric) | 2.5 mL |
| Storage and shipping |
| Content and storage | Upon receipt, store at room temperature or 4°C. Product shipped at room temperature. |
A question or a specific configuration?
Contact us for a quote.