Thermo Scientific™ Pierce™ Quantitative Peroxide Measurement Kit (formulation)

Ref.: BL-RE-101855
€249.00 excl. VAT

Detect and measure hydrogen peroxide (H2O2) levels in biological samples using an iron reagent (Fe) and xylenol orange (XO) reagent for microplates or tubes.

Supplier ref.: 10414195

Content and storage
Suffisant pour : 100 dosages en tubes ou 500 dosages sur microplaque avec échantillons non lipidiques
• Réactif A, 1 ml
• Réactif B, 2 x 50 ml

Store at 4°C.
Description
Pierce Peroxide Quantitative Measurement Kit (Aqueous)
Dose
Quantitative determination of peroxide
Method of detection
Colorimetric
Product range
Pierce™
Brand
Thermo Scientific

Detect and measure hydrogen peroxide levels in biological samples using an orange iron and xylenol reagent with the Thermo Scientific™ Pierce Quantitative Peroxide Measurement Kits.

Detect and measure hydrogen peroxide levels in biological samples using an orange iron and xylenol reagent with the Thermo Scientific™ Pierce Quantitative Peroxide Measurement Kits.

These aqueous and lipid-compatible peroxide assay kits detect peroxides based on ferrous ion oxidation with ferric ion in the presence of orange xylenol. The formulation of the dosing kit is water-friendly and includes sorbitol, which improves sensitivity. On the other hand, the other dosing kit has a formulation that can be used with lipid-based samples without extracting them at first. However, the dosage is less sensitive due to the absence of sorbitol in this kit. Most proteins do not interfere with these assays, although some metal chelators may require the use of white (i.e., control) to mitigate these effects.

In these assays, hydroperoxides convert Fe2+ to Fe3+ at acid pH. Thanks to its water-compatible formulation, peroxide reacts first with sorbitol, transforming it into a peroxyl radical, triggering oxidation of Fe2+ to Fe3+. In the lipid-compatible formulation, peroxide directly transforms Fe2+ into Fe3+. In sulphuric acid solution, Fe3+ forms a complex with the orange colourant of xylenol (XO) to obtain a purple product with a maximum absorbance of 560 nm. The peroxide levels in the test samples can be determined by calculation from the known extinction coefficient of the XO-Fe complex or by reference to a standard curve prepared with hydrogen peroxide solution.

Specificity

Not specific to the target.

Yield

Sufficient for 100 tube strengths or 500 microplate strengths.

Conservation

Storage: Sufficient for: 100 tube strengths or 500 microplate strengths with non-lipid samples• Reactive A, 1 ml• Reactive B, 2 x 50 mlStocker at 4°C.

Compatibility

Designed for use with: Spectrophotometer, microplate reader.

Applications

Detection based on solution, absorbance.

Technical specifications

General
BrandThermo Scientific
Supplier ref. (Fisher Scientific)10414195
Specifications
DescriptionPierce Peroxide Quantitative Measurement Kit (Aqueous)
DoseQuantitative determination of peroxide
Method of detectionColorimetric
Product rangePierce™
Product typeQuantitative determination of peroxide
SpecificityNon-target specific
Sufficient for100 tube strengths or 500 microplate strengths
For use with (application)Solution-based detection, absorbance
For use with (equipment)Spectrophotometer, Microplate Reader
Storage and shipping
Content and storageSufficient for: 100 tube strengths or 500 microplate strengths with non-lipid samples• Reactive A, 1 ml• Reactive B, 2 x 50 mlStocker at 4°C.