Invitrogen™ Human Coagulation Factor VII ELISA Kit

Ref.: BL-RE-106476Manufacturer ref.: EH117RBX5 5 x 96 tests
€2,950.00 excl. VAT

Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.

Accession number
Ai132620 ; Cf7 ; facteur de coagulation VII ; facteur de coagulation VII (accélérateur de conversion de la prothrombine sérique) ; eptacog alfa ; F7 ; facteur 7 ; chaîne lourde du facteur VII ; chaîne légère du facteur VII ; facteur7 ; FVII ; protéine de coagulation FVII ; proconvertine ; Accélérateur de conversion de la prothrombine sérique ; SPCA
Dose range
0.4 to 100 ng/mL
Sensitivity of the dosage
0.4 ng/mL
Conjugate
Biotin
Product type
ELISA
Brand
Invitrogen

Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.

Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.

Coagulation factor VII is a factor dependent on vitamin K essential to l-hemostasis. This factor circulates in the blood as a zymogen and is converted into an active form by factor IXa, factor Xa, factor XIIa or thrombin by minor proteolysis. When factor VII is activated, a heavy chain containing a catalytic domain and a light chain containing 2 EGF-like domains is generated and two chains are maintained together by a disulfide bridge. In the presence of factor III and calcium ions, the activated factor then activates the coagulation cascade by converting factor IX to factor IXa and/or factor x to factor Xa. F7 production defects may cause coagulopathy.

Sensitivity

Sensitivity of the assay: 0.4 ng/mL.

Measurement range

Dose range: 0.4 to 100 ng/mL.

Duration of dosing

Total duration of dosing: 4 h 45 min.

Target

Target: Factor VII.

Samples

Type of sample: Plasma, Serum, Surnatant (plasma volume, 50 µl; Serum, 50 µl; Supernatant, 50 µl).

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)17194859
Specifications
Accession numberAi132620; Cf7; coagulation factor VII; coagulation factor VII (serum prothrombin conversion accelerator); eptacog alfa; F7; factor 7; factor VII heavy chain; factor VII light chain; factor 7; FVII; coagulation protein FVII; proconvertin; Accelerate
Dose range0.4 to 100 ng/mL
Sensitivity of the dosage0.4 ng/mL
ConjugateBiotin
Product typeELISA
Type of samplePlasma, Serum, Surnatant
For use with (equipment)Colorimetric microplate reader
Genetic identification (Enter)P08709
Gene symbol(s)F7
Coefficient of inter-dose variation<12%
Coefficient of intra-dose variation<10%
Contents of kitsPre-coated well plate, standard, dosing diluent concentrate, biotinylated detection antibody, SAV-HRP, washing pad, chromogen, stop solution, adhesive plate lids
Marker or dyeHRP
Quantity5 x 96 tests
Regulatory statusUse exclusively for research
TargetFactor VII
Test time1 h 20 min
Physical characteristics
Volume of samplePlasma, 50 µl; Serum, 50 µl; Supernatant, 50 µl
Storage and shipping
Storage conditions2°C to 8°C
Total duration of dosing4 h 45 min

Origin and customs

Manufacturer ref.EH117RBX5
Country of originUnited States
A question or a specific configuration?
Contact us for a quote.