Invitrogen™ Human Coagulation Factor VII ELISA Kit
Ref.: BL-RE-106476Manufacturer ref.: EH117RBX5 5 x 96 tests
€2,950.00 excl. VAT
Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.
Accession number
Ai132620 ; Cf7 ; facteur de coagulation VII ; facteur de coagulation VII (accélérateur de conversion de la prothrombine sérique) ; eptacog alfa ; F7 ; facteur 7 ; chaîne lourde du facteur VII ; chaîne légère du facteur VII ; facteur7 ; FVII ; protéine de coagulation FVII ; proconvertine ; Accélérateur de conversion de la prothrombine sérique ; SPCA
Dose range
0.4 to 100 ng/mL
Sensitivity of the dosage
0.4 ng/mL
Conjugate
Biotin
Product type
ELISA
Brand
Invitrogen
Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.
Human Coagulation Factor VII quantitates human Coagulation Factor VII in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human Coagulation Factor VII.
Coagulation factor VII is a factor dependent on vitamin K essential to l-hemostasis. This factor circulates in the blood as a zymogen and is converted into an active form by factor IXa, factor Xa, factor XIIa or thrombin by minor proteolysis. When factor VII is activated, a heavy chain containing a catalytic domain and a light chain containing 2 EGF-like domains is generated and two chains are maintained together by a disulfide bridge. In the presence of factor III and calcium ions, the activated factor then activates the coagulation cascade by converting factor IX to factor IXa and/or factor x to factor Xa. F7 production defects may cause coagulopathy.
Sensitivity
Sensitivity of the assay: 0.4 ng/mL.
Measurement range
Dose range: 0.4 to 100 ng/mL.
Duration of dosing
Total duration of dosing: 4 h 45 min.
Target
Target: Factor VII.
Samples
Type of sample: Plasma, Serum, Surnatant (plasma volume, 50 µl; Serum, 50 µl; Supernatant, 50 µl).
Technical specifications
General
Brand
Invitrogen
Supplier ref. (Fisher Scientific)
17194859
Specifications
Accession number
Ai132620; Cf7; coagulation factor VII; coagulation factor VII (serum prothrombin conversion accelerator); eptacog alfa; F7; factor 7; factor VII heavy chain; factor VII light chain; factor 7; FVII; coagulation protein FVII; proconvertin; Accelerate