Invitrogen™ Mouse DLL4 ELISA Kit

Ref.: BL-RE-106537Manufacturer ref.: EM21RBX10 10 x 96 Tests
Price on request
Custom pricing depending on configuration and quantity.

Mouse DLL4 quantitates mouse DLL4 in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant mouse DLL4.

Accession number
AOS6; delta 4; delta ligand 4; delta like canonical Notch ligand 4; Delta4; delta-like 4 (Drosophila); delta-like 4 homolog; delta-like 4 protein; delta-like protein 4; DLL4; Drosophila Delta homolog 4; hdelta2; MGC126344; notch ligand delta-2; notch ligand DLL4; UNQ1895/PRO4341
Dose range
0.2 to 50 ng/mL
Sensitivity of the dosage
0.2 ng/mL
Conjugate
Biotin
Product type
ELISA
Brand
Invitrogen

Mouse DLL4 quantitates mouse DLL4 in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant mouse DLL4.

Mouse DLL4 quantitates mouse DLL4 in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant mouse DLL4.

Sensitivity

Sensitivity of the assay: 0.2 ng/mL.

Measurement range

Dose range: 0.2 to 50 ng/mL.

Duration of dosing

Total duration of dosing: 4 h 45 min.

Target

Target: DLL4.

Samples

Sample type: Supernatant (Serum volume, 50 µL; Plasma, 50 µL; Supernatant, 50 µL).

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)18527814
Specifications
Accession numberAOS6; delta 4; delta ligand 4; delta like canonical Notch ligand 4; Delta4; delta-like 4 (Drosophila); delta-like 4 homolog; delta-like 4 protein; delta-like protein 4; DLL4; Drosophila Delta homolog 4; hdelta2; MGC126344; notch ligand delta-2; notch ligand DLL4; UNQ1895/PRO4341
Dose range0.2 to 50 ng/mL
Sensitivity of the dosage0.2 ng/mL
ConjugateBiotin
Product typeELISA
Type of sampleSupernatant
For use with (equipment)Colorimetric Microplate Reader
Genetic identification (Enter)Q9JI71
Gene symbol(s)Dll4
Coefficient of inter-dose variation<12%
Coefficient of intra-dose variation<10%
Contents of kitsPre-coated 96 well flat, Standard, Assay Dilute Concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers
Marker or dyeHRP
Quantity10 x 96 Tests
Regulatory statusResearch Use Only
TargetDLL4
Test time1 hr 20 min
Physical characteristics
Volume of sampleSerum, 50 µL; Plasma, 50 µL; Supernatant, 50 µL
Storage and shipping
Storage conditions2°C to 8°C
Total duration of dosing4 hr 45 min

Origin and customs

Manufacturer ref.EM21RBX10
Country of originUnited States
HS customs code3002 15 00 00
A question or a specific configuration?