The urine creatinine detection kit, for research purposes only, is a colorimetric test designed for the quantification and detection of creatinine in human urine, rat, dog and monkey samples. The...
The urine creatinine detection kit, for research purposes only, is a colorimetric test designed for the quantification and detection of creatinine in human urine, rat, dog and monkey samples. Mouse urine samples are not compatible with the use of this assay for the detection of glomerular filtration rate (creatinine clearance).
This complete ready-to-use kit includes one or more 96-well transparent plates, a creatinine standard, a creatinine detection reagent and other components for dosing. This kit requires the use of a 96-well microplate reader capable of reading optical density at 490 nm, preferably with a correction between 570 and 590 nm.
Performance characteristics
• Type of dosage: colorimetric detection kit
• Sample types: human urine, rat, dog and monkey samples
• Sensitivity: 0.019 mg/dl
• Standard curve range: 0.3–20 mg/dl
• Reactivity: independent of species
Creatinine (2-amino-1-méthyl-5H-imadazol-4-one) is a metabolite of phosphocreatin (p-creatin), a molecule used as storage for high-energy phosphate that can be used by tissues for the production of d的ATP. Creatine comes from diet or is synthesized from amino acids arginine, glycine and methionine. This occurs in the kidneys and liver, although other organic systems may be involved and species-specific differences may exist. Creatine and p-creatin are transformed in a non-enzymatic manner into a metabolite creatinine that spreads into the blood and is excreted by the kidneys. In vivo, this conversion appears irreversible and in vitro, it is favored by higher temperatures and lower pH. Creatinine is formed spontaneously from p-creatin. This assay is intended to measure creatinine from a wide range of sources.
The creatinine detection kit in urine is designed to quantitatively measure creatinine in urine samples. A creatinine standard is provided to generate a calibration curve for the assay and all samples must be read from the calibration curve. The diluted standards or samples shall be piped into a transparent microtitration plate. The color-producing reaction is triggered by the creatinine detection reagent, which is piped into each well. After a short incubation, the intensity of the generated color is detected in a microtitration plate reader capable of measuring the wavelength of 490 nm. The Jaffe reaction used in this kit was modified to read creatinine levels in the urine.
Samples
Type of sample: Urine.
Conservation
Storage: 96 well plates, standards, other dosing reagents, buffers and batch-specific data sheet. Store at –20°C.
Compatibility
Designed for use with: Microplate reader.
Packaging
Packaging: 2 x 96 tests.
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 15783779 |
| Specifications |
| Method of detection | Colorimetric |
| Immunoassay kit format | Detection kit |
| Product type | Creatinine detection kit in urine |
| Type of sample | Urine |
| For use with (equipment) | Microplate reader |
| Genetic identification (Enter) | Non-coding |
| Gene symbol(s) | Non-coding |
| Quantity | 2 x 96 tests |
| Target kit named | Urinary creatinine |
| Storage and shipping |
| Content and storage | 96 well plates, standard, other dosing reagents, buffers and batch-specific data sheet.
Store at –20°C. |
| Shipping conditions | Approved for shipments on dry ice or wet |
Origin and customs
| Manufacturer ref. | EIACUN |
|---|
| Country of origin | United States |
|---|
| HS customs code | 3822 90 00 00 |
|---|
A question or a specific configuration?