The Thermo Scientific Pierce triple quadripole calibration solution, a wide mass range, is a mixture of 14 highly pure and ionisable components (mass range: 69 m/z to 2,800 m/z) designed for use in...
The Thermo Scientific Pierce triple quadripole calibration solution, a wide mass range, is a mixture of 14 highly pure and ionisable components (mass range: 69 m/z to 2,800 m/z) designed for the positive and negative ionization calibration of the Thermo Scientific triple quadripole instruments.
Improved mass accuracy: extended mass range designed to improve mass accuracy compared to existing calibration solutions Calibration in positive and negative mode: unique formulation with extended mass ranges for both calibration modes of ionization Highly validated formulation: high quality, rigorously tested with batch-specific test certificates Ready to use: the reference standard can be directly loaded into a syringe and injected into the Stable instrument: store between 2 and 8°C for 18 monthsThe Pierce triple quadripole calibration solution is a ready-to-use formulation optimized for the positive and negative ionization calibration of the instruments. The extended masses (from 69 m/z to 2.800 m/z) improve the performance of the Thermo Scientific Quantiva™ and Endura™ Triple Quadrupole mass spectrometers. In addition, the triple quadripole calibration solution, a wide mass range, is manufactured in a ISO 9001 certified facility and each batch undergoes quality control according to strict specifications. The stable solution is supplied in a watertight, high-purity PTFE vial.The formulation of the Pierce triple quadripole calibration solution, a wide mass range, contains 14 ionisable compounds in positive and negative modes for instrument calibration. The formulation has been specially optimized for use with TSQ Endura™ Series and TSQ Quantiva™ Series instruments. The calibration solution is also compatible with TSQ Quantum™ Series#, TSQ Discovery™ Series#, TSQ Quantum Ultra™ Series#, TSQ Quantum Access™ Series# and TSQ Vantage™ Series# using the recommended mass list.Positive mode (m / Z): 69.0447, 142.1590, 322.0481, 622.0289, 922.0098Mode negative (m / Z): 59.0128, 112.9845, 301.9970, 601.97799, 1 033.9870Pour the calibration procedure, use:Start guide of the TSQ series (70111-97152).
Conservation
Storage: 1 x 10 mlTocker in refrigerator (2 to 8°C).
Compatibility
Designed for use with: Mass spectrometer.
Pierce™ range
It is part of the Pierce™ range.
Technical specifications
| General |
| Brand | Thermo Scientific |
| Supplier ref. (Fisher Scientific) | 15322627 |
| Specifications |
| For use with (equipment) | Mass spectrometer |
| Product type | Calibration solution |
| Product range | Pierce™ |
| End product type | Peptides, small molecules |
| Method of detection | Mass spectrometry |
| Workflow stage | Calibration |
| Shape | Liquid |
| Materials |
| Starting material | Peptides, small molecules |
| Storage and shipping |
| Content and storage | 1 x 10 mlStocker in refrigerator (2 to 8°C). |