Thermo Scientific™ Centrifugation Columns for the Elimination of Detergents & Plates

Ref.: BL-RE-127338 5 mL
€294.00 excl. VAT

Rapidly remove high detergent concentrations with minimal loss of samples from detergent removal resins. Thermo Scientific HiPPR (High Protein and Peptide Recovery) is recommended for protein concentrations up to 100 μg/ml, while Thermo Scientific Pierce is suitable for concentrations above 100 μg/ml.

Supplier ref.: 12301883

Description
Kit
Product type
Kit for the disposal of detergents
Content and storage

• Résine d’extraction des détergents, 5 ml
• Kit d’accessoires pour colonnes de centrifugation, 54 colonnes

Store at 4°C.
Column type
Proprietary resin, affinity
Stationary phase
Ligand owner
Brand
Thermo Scientific

The detergents and surfactants used to prepare protein and peptide samples may interfere with ELISA analysis, isoelectric focus and mass spectrometry (MS).

The detergents and surfactants used to prepare protein and peptide samples may interfere with ELISA analysis, isoelectric focus and mass spectrometry (MS). The removal of detergents from peptide samples is particularly difficult and critical for MS analysis. Even low levels of detergents contaminate the instruments and disrupt the bonding of the columns, the peptides' l ́ellution and ionization. The removal resin of HiPPR and Pierce detergents is ideal for the rapid removal of current detergents from tryptic digestions to improve the results of LC-MS/MS and MALDI-MS analyses.


• Optimized: removes > 95% detergent from protein or peptide samples
• Fast: Sample processing takes less than 15 minutes
• Effective: eliminates detergent interference in downstream applications such as ELISA, isoelectric focus and mass spectrometry.

Pierce detergent removal resin Pierce detergent removal resin effectively binds to high detergent concentrations and removes them from samples of 10 µl to 1 ml with minimal sample loss. These microcentrifugation columns are prepackaged with different volumes of exclusive resin and are ideal for the treatment of samples with a protein or peptide concentration greater than 100 µg/ml.

Yield

Sufficient for 54 samples.

Conservation

Storage: • Resin for extraction of detergents, 5 ml• Kit accessories for centrifugation columns, 54 columnsKeep at 4°C.

HiPPR™ range

It is part of the HiPPR™ range.

Technical specifications

General
BrandThermo Scientific
Supplier ref. (Fisher Scientific)12301883
Specifications
DescriptionKit
Product typeKit for the disposal of detergents
Column typeProprietary resin, affinity
Stationary phaseLigand owner
Product rangeHiPPR™
Purification targetElimination of detergents
Sufficient for54 samples
Quantity5 mL
Storage and shipping
Content and storage• Resin for detergent extraction, 5 ml• Kit of accessories for centrifugation columns, 54 columnsKeep at 4°C.
A question or a specific configuration?
Contact us for a quote.

Supplier ref.: 12301883