Immobilize polyclonal antibodies or other glycoproteins on d-agarose balls for immunoprecipitation or co-precipitation assays via periodate oxidized sugars.
Supplier ref.: 11648843
Capacity (metric)
2 to 10 µg of oxidized or glycoprotein-coupled antibodies for 20 µl resin
Content and storage
Suffisant pour : 25 réactions IP / Co-IP, chacune utilisant 20 µl de résine couplée à un anticorps • Résine d’hydrazide UltraLink, 0,5 ml • Tampon de couplage GlycoLink, 50 ml • Aniline, 0,2 ml • Sodium meta-periodate, 0.5 g • Tampon de lavage, 60 ml • Colonnes de centrifugation de dessalage Zeba, 0,5 ml, 25 colonnes • Tampon de lavage / lyse d’IP, 50 ml • Box PBS (to obtain 500 ml), 1 box • Tampon d’élution, pH de 2,8, 50 ml • Tampon d’échantillon avec marqueur de piste, non réducteur (5X), 5 ml • Bouchons à vis à de colonne de centrifugation Pierce, 25 colonnes • Tubes de prélèvement, 2 ml, 100 tubes
Store at 4°C.
Dose
Affinity purification
For use with (equipment)
microcentrifuge
Product range
GlycoLink™
Brand
Thermo Scientific
The d的IP Thermo Scientific GlycoLink kit provides components for effective immunoprecipitation (IP and co-IP) based on small-scale, covalent immobilization of antibody affinity resin and other...
The Thermo Scientific GlycoLink kit provides components for effective immunoprecipitation (IP and co-IP) based on small-scale, covalent immobilization of antibody affinity resin and other glycoproteins via oxidized sugar groups.
The GlycoLink kit uses UltraLink resin activated by hydrazide to immobilize and perform 25 IP or Co-IP assays with different antibodies or glycoprotein ligands. The method is ideal for polyclonal antibodies, which usually have abundant carbohydrates (glycosylation) on their Fc fragments. Monoclonal antibodies containing adequate carbohydrates are also effective. Antibodies immobilized by this hydrazide-glucose method have unobstructed antigenic binding sites and optimal purification capacity. Prepared glycoprotein or antibody columns may be regenerated and reused at least five times for immunoprecipitation, coimmunoprecipitation or affinity purification without significant loss of binding capacity.
Key points: Effective immobilization: perform 2-10 μg of oxidized antibodies or other glycoproteins at 20 μl resin in 2 hours or less Stable immobilization: the resonance structure of hydrazone bonds is stable enough to keep the antibody coupled during the elution Preservation of the binding function: immobilise l-IgG via the Fc region, This helps to preserve the availability of both antigen binding sites to capture the target Multi-purpose applications: immobilise any molecule containing oxidable sugars, including glycoproteins, for use in the purification of protein-binding partners.
Target
Target: Not specific to the target.
Yield
Sufficient for 25 reactions.
Compatibility
Designed for use with: microcentrifuge.
Applications
Immunoprecipitation (IP).
Capacity
Capacity: 2 to 10 µg of oxidized or glycoprotein-coupled antibodies for 20 µl resin.
Technical specifications
General
Brand
Thermo Scientific
Supplier ref. (Fisher Scientific)
11648843
Specifications
Dose
Affinity purification
For use with (equipment)
microcentrifuge
Product range
GlycoLink™
Quantity
1 kit
For use with (application)
Immunoprecipitation (IP)
Target
Non-target specific
Type
Kit IP
Sufficient for
25 reactions
Format
Kit
Physical characteristics
Capacity (metric)
2 to 10 µg of oxidized or glycoprotein-coupled antibodies for 20 µl resin