Thermo Scientific™ AminoLink™ Plus Immobilization Kit, 2 mL

Ref.: BL-RE-127550 Set of 1 columns
€170.00 excl. VAT

Covalent coupling of antibodies and other proteins via primary amines (-NH2) for affinity purification with these l-activated d-agarose balls.

Supplier ref.: 10445335

Capacity (metric)
2 to 40 mg of protein immobilization per column
Formula
Multicomponent kit with 1 resin column of 2 ml
Content and storage
Sufficient for: Capitalization of 2 to 40 mg of protein per column
• Colonne AminoLink Plus, 2 ml, 1 colonne
• Box of PBS (for 500 ml), 1 box
• Citrate carbonate buffer boxes (for 500 ml), 1 box
• Sodium cyanoborohydride solution, 5M, 0.5 ml
• extinguishing buffer, 15 ml
• Wash solution, 50 ml
• Column accessories

Store at 4°C.
Product range
AminoLink™
Quantity
Set of 1 columns
Brand
Thermo Scientific

Thermo Scientific™ AminoLink Plus kits and coupling resin use l-activated d-agarose balls for high-efficiency covalent coupling of antibodies (proteins) via primary amines for the use of the...

Thermo Scientific™ AminoLink Plus kits and coupling resin use aldehyde-activated d-agarose balls for high-efficiency covalent antibody (protein) coupling via primary amines for the preparation of affinity purification columns.

Resins and kits use activated d-agarose balls and robust coupling chemistry to immobilize proteins and other ligands through primary amines (-NH2) in the resin. Once an antibody or other ligand is immobilized, prepared affinity resin can be used for various purification methods involving batch or column chromatography. Resin and bonding are stable under binding and elution conditions generally used in affinity chromatography, allowing the prepared resin to be used over 10 cycles of purification by minimum affinity.

The AminoLink Plus coupling reaction involves the spontaneous formation of Schiff base bonds between aldehydes (on the support) and amines (on the ligand) and subsequent stabilization by incubation with a mild reducing agent (sodium cyanoborohydride). The entire coupling reaction, called reducing amination, occurs between 4 and 6 hours in single non-amone buffers such as PBS. The effectiveness of coupling with antibodies and standard proteins is generally greater than 85%, producing between 1 and 20 mg of immobilized protein per millilitre of d-agarose balls.

Target

Target: Antibody, protein via primary l.

Yield

Sufficient for 2 to 40 mg protein per column.

Formulation

Formulation: Multicomponent kit with 1 2 ml resin column.

Capacity

Capacity: 2 to 40 mg of protein immobilization per column.

AminoLink™ range

It is part of the AminoLink™ range.

Technical specifications

General
BrandThermo Scientific
Supplier ref. (Fisher Scientific)10445335
Specifications
FormulaMulticomponent kit with 1 resin column of 2 ml
Product rangeAminoLink™
QuantitySet of 1 columns
TargetAntibody, proteins via primary l-amine
TypeLock-in kit
Stationary phaseAldehydes
Sufficient for2 to 40 mg protein per column
FormatCentrifugation column
Column typeAffinity, d-agarose resin
Physical characteristics
Capacity (metric)2 to 40 mg of protein immobilization per column
Storage and shipping
Content and storageSufficient for: Capitalization of 2 to 40 mg protein per column• AminoLink Plus column, 2 ml, 1 column• PBS box (for 500 ml), 1 box• Citrate carbonate buffer boxes (for 500 ml), 1 box• Sodium cyanobrobrohydroide solution, 5M, 0.5 ml• quench buffer, 15 ml• Wash solution, 50 ml• Column accessories Store at 4°C.
A question or a specific configuration?
Contact us for a quote.

Supplier ref.: 10445335