Invitrogen APEX antibody marking kits allow you to mark small amounts of IgG (10–20 μg) antibodies covalently with Alexa Fluor dyes or biotin, even in the presence of contaminants, stabilizers, and other...
Invitrogen APEX antibody marking kits allow you to covalently mark small amounts of IgG antibodies (10–20 μg) with Alexa Fluor dyes or biotin, even in the presence of contaminants, protein stabilizers or buffers containing amines (e.g. BSA, Tris or glycine). APEX antibody marking kits have a resin tip that captures the IgG antibody, allowing the contaminants to be removed before the labeling reaction with the choice conjugate. After application of the fluorophore reactive to the resin-bound IgG antibody to amine, a fluorescent conjugate to IgG is formed and then eluted from the resin using the elution buffer. Each kit contains everything you need for five marking reactions. The working IgG antibody conjugate can be reached in about 2 hours 30 (with about 15 minutes of handling time).
Invitrogen APEX antibody marking kits allow covalent adhesion of a fluorophore or biotin to small amounts of IgG antibodies (- 10 to 20 µg), even in contaminated mixtures or biological sample solutions. They are perfect for effective marking antibodies in serum, d-ascites or d-hybridoma suspensions. The marked antibodies are ready to be used in imaging or flow cytometry applications in just 2 hours 30 with little handling time.
Important characteristics of APEX antibody marking kits:
· Marked anticorps usually ready for use in 2 hours 30 (-15 minutes of handling time)
· Designed to score 10 to 20 µg of IgG
· Covalent adherence of Alexa Fluor dyes or biotin
· Compatible with contaminant proteins or stabilizers such as BSA
· Choose from the colouring agents Alexa Fluor 488, 555, 568, 594 and 647, Pacific Blue or Biotin-XX
No problem with contaminant proteins or protein stabilizers
Many IgG antibodies are often only available in small quantities and are packed with protein stabilizers, such as BSA, or other contaminants that may interfere with amine-reactive labeling reagents. APEX antibody marking kits avoid this problem by using a solid phase marking technique that captures IgG antibodies on a specialized resin inside the APEX antibody marking tip. Contaminants are simply elucidated through the tip before the application of reactive marking to amines.
Improved results and workflows with marked primary antibodies
A primary antibody directly marked with a fluorophore often produces less background fluorescence and a low non-specific binding. Moreover, multiple primary antibodies of the same isotype or derived from the same species can be easily used in the same experiment if they are directly marked with compatible fluorophores.
Customization possible
Can't find what you're looking for in our inventory list? We can prepare a custom antibody conjugate for you. Our personalized conjugation service is efficient and confidential, and we believe in the quality of our work. We are certified ISO 9001:2000.
Technical specifications
| General |
| Brand | Invitrogen |
| Specifications |
| Quantity | 5 reactions |
| Labelling balance | 10 to 20 μg |
| Chemical responsiveness | Amine |
| Labeling Target | IgG |
| Storage and shipping |
| Content and storage | Store between 2° to 6°C, at the desiccator, away from light and do not freeze. |
A question or a specific configuration?
Contact us for a quote.