Human DCBLD2/ESDN quantitates human DCBLD2/ESDN in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human DCBLD2/ESDN.
Human DCBLD2/ESDN quantitates human DCBLD2/ESDN in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human DCBLD2/ESDN.
This protein is a key enzyme in the catabolic pathway of odd chain fatty acids, l的isoleucine, threonine, methionine and valine. It is probably a dodecaamer composed of six alpha subunits containing biotin and six beta subunits. The protein is found in the mitochondrial matrix. The defects in the PCCA are the cause of propionic acidaemia type I (PA-1) [MIM:606054]. PA-1 is a fatal disease characterized by episodic vomiting, lethargy and ketosis, neutropenia, periodic thrombocytopenia, hypogammaglobulinemia, mental retardation and protein intolerance.
Sensitivity
Sensitivity of the assay: 0.041 ng/mL.
Measurement range
Dose range: 0.041 to 10 ng/mL.
Duration of dosing
Total duration of dosing: 4 h 45 min.
Samples
Type of sample: Plasma, Serum, Surnatant (plasma volume, 50 µl; Serum, 50 µl; Supernatant, 50 µl).
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 17134899 |
| Specifications |
| Accession number | 1700055P21Rik; AW146002; CLCP1; protein 1 of the coagulation factor V/VIII homology domains; protein 1 of the V/VIII homology domains, CUB, LCCL; Dcbld2; discoidin; discoidin 2 protein; discoidin, CUB and LCCL; neuropiline-like protein |
| Dose range | 0.041 to 10 ng/mL |
| Sensitivity of the dosage | 0.041 ng/mL |
| Conjugate | Biotin |
| Product type | ELISA |
| Type of sample | Plasma, Serum, Surnatant |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | Q96PD2 |
| Gene symbol(s) | DCBLD2 |
| Coefficient of inter-dose variation | <12% |
| Coefficient of intra-dose variation | <10% |
| Contents of kits | Pre-coated well plate, standard, dosing diluent concentrate, biotinylated detection antibody, SAV-HRP, washing pad, chromogen, stop solution, adhesive plate lids |
| Marker or dye | HRP |
| Quantity | 5 x 96 tests |
| Regulatory status | Use exclusively for research |
| Target | DCBLD2 |
| Test time | 1 h 20 min |
| Physical characteristics |
| Volume of sample | Plasma, 50 µl; Serum, 50 µl; Supernatant, 50 µl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 4 h 45 min |
Origin and customs
| Manufacturer ref. | EH148RBX5 |
|---|
| Country of origin | United States |
|---|
A question or a specific configuration?
Contact us for a quote.