Kit ELISA Thrombopoietin sandwich (TPO) (human): quantitative assay of Hu TPO in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Hu TPO.
Kit ELISA Thrombopoietin sandwich (TPO) (human): quantitative assay of Hu TPO in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Hu TPO.
Method principle: This ELISA solid phase sandwich test (immuno-enzymatic dose) measures the amount of target bound between a pair of matched antibodies. A specific target antibody is pre-adsorbed into the wells of the supplied microplate. Samples, standards or controls are added to these wells and bind to immobilized antibodies (capture antibodies). The sandwich is formed by adding the second antibody (detection antibody), then a substrate solution reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this signal is directly proportional to the concentration of the target present in the original sample.
Rigorous validation: Each batch manufactured from this ELISA kit is checked for criteria such as sensitivity, specificity, accuracy and reproducibility from one batch to another (see the package leaflet for more information on validation).
Thrombopoietin (TPO, THPO, MPL ligand, stimulation factor of megakaryocyte colonies) is responsible for platelet generation by its action on haematopoietic cells engaged in megakaryocyte lineage. The binding of thrombopoietin to its receptor, MPL (CD110), triggers a cascade of signaling via the JAK/STAT, MAPK and PI3K/AKT signaling pathways leading to the proliferation and differentiation of megakaryocytes and ultimately to platelet production (thrombopoiesisis). Thrombopoietin is produced constitutively by the liver and has a pre-estimated molecular weight of 38 kDa.
Sensitivity
Sensitivity of the dosage: 90 pg/ml.
Measurement range
Dose range: 93.75 to 6.000 pg/ml.
Duration of dosing
Total dosage duration: 4 hours 45 min.
Reproducibility
Coefficient of intradose variation < 10%, interdose < 12%.
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 17844220 |
| Specifications |
| Accession number | P40225 |
| Dose range | 93.75 to 6 000 pg/ml |
| Sensitivity of the dosage | 90 pg/ml |
| Calibration range | 90 pg/ml at 6.000 pg/ml |
| Dose | ELISA solid-phase sandwich |
| Conjugate | Biotin |
| Product type | Kit ELISA |
| Protein family | Growth Factors & Receivers |
| Type of sample | Plasma, Serum, Surnatant |
| Specificity | This ELISA kit shows no cross-reactivity with the following tested cytokines: Human BDNF, BLC, ENA-78, FGF-4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-9, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF, GM-CSF, IFN-gamma, leptine (OB), MCP-1, MCP-2, MC |
| Sufficient for | 10 x 96 dosages |
| Target species | Human |
| For use with (application) | ELISA, protein dosage, protein biology, cancerology, immunology, neuroscience, neurobiology, protein detection, protein analyses |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | 7066 |
| Gene symbol(s) | MGDF,MKCSF,ML,MPLLG,THCYT1,TPO |
| Coefficient of inter-dose variation | < 12% |
| Coefficient of intra-dose variation | < 10% |
| Contents of kits | Stop solution, Stalcon, Wash pad, SAV-HRP, Adhesive plate covers, 96-well pre-coated plate, Chromogen, Dose diluent concentrate, Biotinylated detection antibody |
| Marker or dye | HRP |
| Quantity | 10 x 96 tests |
| Regulatory status | RUO |
| Research disciplines | Cellular cycle & proliferation |
| Synonym | MGDF, MKCSF, ML, MPLLG, THCYT1, TPO |
| Target | Human |
| Test time | 1 hour 20 minutes |
| Physical characteristics |
| Volume of sample | Plasma, 50 μl; serum, 50 μl; supernatant, 100 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 4 hours 45 minutes |
Origin and customs
| Manufacturer ref. | EHTHPOX10 |
|---|
| Country of origin | United States |
|---|
| HS customs code | 3002 12 00 00 |
|---|
A question or a specific configuration?