Invitrogen™ Kit ELISA™ Instant Human MCP-1

Ref.: BL-RE-144071Manufacturer ref.: BMS281INST 128 Tests
€774.00 excl. VAT

The ELISA test for the human monocyte 1 chemotactic protein (MCP-1) quantifies human MCP-1 in serum, plasma, cell culture supernatants or other human body fluids. The test will recognize the...

Accession number
P13500
Dose range
15.6-1.000 pg/ml
Sensitivity of the dosage
2.31 pg/ml
Conjugate
HRP
Product type
Kit ELISA
Brand
Invitrogen

The ELISA test for the human monocyte 1 chemotactic protein (MCP-1) quantifies human MCP-1 in serum, plasma, cell culture supernatants or other human body fluids. The test will recognize the...

The ELISA test for the human monocyte 1 chemotactic protein (MCP-1) quantifies human MCP-1 in serum, plasma, cell culture supernatants or other human body fluids. The test will exclusively recognize natural and recombinant MCP-1 Hu. Method Principle The ELISA Human MCP-1 Sandwich (Immuno-Enzymatic Test) test is designed to measure the amount of the target bound between a pair of matched antibodies. A target-specific antibody was pre-vested in the wells of the supplied microplate. Samples or controls are then added to these wells and are linked to immobilized antibodies (capture). The sandwich is formed by binding the second antibody (detector) to the target on a different epitope from the capture antibody. An antibody conjugated with the enzyme binds the formed sandwich. After incubation and washing steps to remove the microplate from the non-bonded substances, a substrate solution reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this coloured product is directly proportional to the concentration of TP (p) present in the original sample. Rigorous validation Each batch manufactured from this ELISA kit is tested for quality for criteria such as sensitivity, specificity, accuracy and batch-to-batch consistency. See the product manual for more information on validation.

MCP-1 (monocytic chemotactic protein-1, CCL2) has a pre-determined molecular weight of approximately 11 kDa, however, it may have a higher molecular weight due to glycosylation. MCP-1 is a member of the cytokine family and plays an important role in immunoreguulation and inflammation processes. The signals of MCP-1 via G-linked receptors, CCR2 and CCR4, to recruit memory T cells, monocytes and dendritic cells. MCP-1 is related to tumour progression, l-angiogenesis, and has selective chemotactic activity towards monocytes and basophiles, but not towards neutrophils or eosinophils. MCP-1 is produced by various cell types and is a potent chemotactic for monocytes, memory T-cells and natural killer cells (NK). In addition, MCP-1 appears in the etiology of several immune disorders and is regulated during infection and inflammation. Although MCP-1 is a powerful activator of basophiles, the associated MCP-2 protein stimulates eosinophils and basophiles. The MCP-3 was shown to have the greatest influence. MCP-1 has been involved in the pathogenesis of diseases characterized by monocytic infiltrates, such as psoriasis, rheumatoid arthritis, or atherosclerosis.

Sensitivity

Sensitivity of the dosage: 2.31 pg/ml.

Measurement range

Dose range: 15.6-1.000 pg/ml.

Duration of dosing

Total duration of dosing: 3 h 10 min.

Reproducibility

Coefficient of variation intra-dose 7.7%, inter-dose 6.2%.

Target

Target: Human.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)15551877
Specifications
Accession numberP13500
Dose range15.6-1.000 pg/ml
Sensitivity of the dosage2.31 pg/ml
ConjugateHRP
Product typeKit ELISA
Type of sampleAmniotic liquid, Serum, Surnatant, Supernatant
Target speciesHuman
For use with (application)ELISA
For use with (equipment)Colorimetric microplate reader
Genetic identification (Enter)6347
Gene symbol(s)GDCF-2,HC11,HSMCR30,MCAF,MCP-1,MCP1,SCYA2,SMC-CF
Coefficient of inter-dose variation6.2%
Coefficient of intra-dose variation7.7%
Contents of kits96-well pre-coated microplate, Antibodies detection, Sample thinner, Sample thinner, lyophilized, Wash buffer concentrate, Substrate solution, Stop solution, Stop solution, 10x lysis pad, Adhesive plate covers
Marker or dyeHRP
Quantity128 Tests
Regulatory statusRUO
SynonymChemoatractive protein of monocytes 1, MCAF, HC11
TargetHuman
Test time20 min
Physical characteristics
Volume of sampleAmniotic liquid, 20 μl; plasma, 20 μl; serum, 20 μl; supernatant, 20 μl
Storage and shipping
Storage conditions-20°C
Total duration of dosing3 h 10 min

Origin and customs

Manufacturer ref.BMS281INST
Country of originAutriche
HS customs code3002 15 00 00
A question or a specific configuration?
Contact us for a quote.