The Thermo Scientific™ Pierce IgG Plus orientation kits bind and retaculate the D-Agarose Resin antibody of protein A or protein G, creating a reusable affinity column for purification of the protein A or protein G.
The Thermo Scientific™ Pierce IgG Plus orientation kits bind and retact antibodies to the d'agarose resin of protein A or protein G, creating a reusable affinity column for antigen purification.
These d-IgG orientation kits use a cross-linking agent to covalencely attach antibodies bound to the d-agarose resin of protein A or protein G, creating a reusable affinity column for antigen purification. Guidance Kits Plus allow antibodies to be immobilized more effectively and stable than the traditional orientation method because they use the DSS (suberate disuccinimidyl) cross-linking agent NHS instead of the DMP (dimethyl pimelimelidate) cross-linking agent of imidoester. Several milligrams of IgG can be bound and crosslinked to each 2 ml column, then the prepared affinity column can be used several times for antigen purification using typical binding and d
The immobilization method is called orientation because antibodies are first captured in the affinity resin through their Fc regions, which are the target binding sites of protein A and protein G ligands. Thus, antibodies are linked with their externally oriented antigen binding sites. DSS cross-linking agent reacts with primary amines (lateral lysine residue chain) of protein A/G and affinity-bound antibody, allowing for covalence and permanent fixation of proteins.
Yield
Sufficient for 1 to 6 mg of IgG mice per column.
Pierce™ range
It is part of the Pierce™ range.
Technical specifications
| General |
| Brand | Thermo Scientific |
| Supplier ref. (Fisher Scientific) | 10289923 |
| Specifications |
| Product range | Pierce™ |
| Type | G IgG Plus Protein Orientation Kit |
| Stationary phase | Protein G |
| Sufficient for | 1 to 6 mg d-IgG of mice per column |
| Format | Centrifugation column |
| Column type | Affinity, d-agarose resin |
| Physical characteristics |
| Capacity (metric) | 2 mL |
| Storage and shipping |
| Content and storage | Sufficient for: Immobilisation of 1 to 6 mg d的IgG of mice per column• Columns of protein G, 2 ml, 2 columns• Disuccinimidyl suberate (DSS), 2 x 13 mg• Box PBS (provides 500 ml), 1 box• Blocking stamp, 6 ml• IgG elution stamp, 15 ml• Linking of antibodies / washing pad, 120 ml• Column accessoriesKeep at 4°C. |
A question or a specific configuration?