Invitrogen™ Kit ELISA™ Instant ICAM-1 (soluble) human

Ref.: BL-RE-162056Manufacturer ref.: BMS201INST 128 Tests
€774.00 excl. VAT

The Human Soluble Intercellular Adhesion Molecule 1(Hu sICAM-1) ELISA quantitates Hu sICAM-1 in human serum, plasma, cell culture supernatants, urine, amniotic fluid, bile, or other body fluids. The assay will exclusively recognize both natural and…

Accession number
P05362
Dose range
1.56-100 ng/ml
Sensitivity of the dosage
2.17 ng
Conjugate
HRP
Product type
Kit ELISA
Brand
Invitrogen

The Human Soluble Intercellular Adhesion Molecule 1(Hu sICAM-1) ELISA quantitates Hu sICAM-1 in human serum, plasma, cell culture supernatants, urine, amniotic fluid, bile, or other body fluids. The assay will exclusively recognize both natural and…

The Human Soluble Intercellular Adhesion Molecule 1(Hu sICAM-1) ELISA quantitates Hu sICAM-1 in human serum, plasma, cell culture supernatants, urine, amniotic fluid, bile, or other body fluids. The assay will exclusively recognize both natural and recombinant Hu sICAM-1. Principle of the method The Human sICAM-1 solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the binding of the second (detector) antibody to the target on a different epitope from the capture antibody. An antibody conjugated with enzyme binds the formed sandwich. After incubation and washing steps to rid the microplate of unbound substances, a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, and lot-to-lot consistency. See manual for more information on validation.

The ICAML-1 (CD54) is a single chain type 1 integrated membrane glycoprotein of 85-110 kDa with an extracellular domain of five superfamily repeats of immunoglobulins, a transmembrane region, and a cytoplasmic domain. The ICAM-1 has 7 potential N-binding glycosylation sites and shares a significant amino acid sequence homology with ICAM-3 (CD50) and ICAM-2 (CD102). The ICAM-1 binds to CD11a/CD18 (leukocyte adhesion molecular, LFA-1) or CD11b/CD18 (Mac-1) integrins and is operated by Rhinovirus as a receptor. The ICAM-1 is expressed as activated endothelial cells detected on epithelial cells, fibroblasts, chondrocytes, B cells, T cells (low), monocytes, macrophages, dendritic cells and neutrophils, with relatively low levels that increase at the time of inflammation. L的ICAM-1 is also detected in some carcinomas and melanoma cells. Soluble L的ICAM 1 is detectable in plasma and is elevated in patients with various inflammatory syndromes.

Sensitivity

Sensitivity of the dosage: 2.17 ng.

Measurement range

Dose range: 1.56-100 ng/ml.

Duration of dosing

Total duration of dosing: 2 h 10 min.

Reproducibility

Coefficient of intra-dose variation 9.5%, inter-dose 12.9%.

Target

Target: Human.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)15511507
Specifications
Accession numberP05362
Dose range1.56-100 ng/ml
Sensitivity of the dosage2.17 ng
ConjugateHRP
Product typeKit ELISA
Type of sampleAmniotic liquid, Serum, Surnatant, Serum, Supernatant, Urine
Target speciesHuman
For use with (application)ELISA
For use with (equipment)Colorimetric microplate reader
Genetic identification (Enter)3383
Gene symbol(s)BB2,CD54,P3.58
Coefficient of inter-dose variation12.9%
Coefficient of intra-dose variation9.5%
Contents of kitsAdhesive Plate Covers, Antibodies Detection, 10x lysis pad, 96 well pre-coated microplate, Sample thinner, lyophilized, Stop solution, Substrate solution, Wash buffer concentrate, Stable curve strips, Adhesive Plate Covers
Marker or dyeHRP
Quantity128 Tests
Regulatory statusRUO
SynonymIntercellular adhesion molecule 1, CD54 antigen
TargetHuman
Test time20 min
Physical characteristics
Volume of sampleAmniotic liquid, 10 μl; bile, 10 μl; plasma, 10 μl; serum, 10 μl; supernatant, 10 μl; urine, 10 μl
Storage and shipping
Storage conditions-20°C
Total duration of dosing2 h 10 min

Origin and customs

Manufacturer ref.BMS201INST
Country of originAutriche
HS customs code3002 15 00 00
A question or a specific configuration?
Contact us for a quote.