| Brand | Thermo Scientific |
| B-LABO ref. | BL-EQ-173376 |
| Manufacturer ref. | DO213 |
| Includes | Meter with stand (PSTAR2130), polarographic DO/ATC electrode with calibration sleeve (083005MD), polarographic DO electrode maintenance kit, BOD adapter |
|---|
| Barometric pressure correction | Yes, automatic with built-in barometer or manual |
|---|
| Outputs | USB flash drive, computer or printer (STARA-106) |
|---|
| For use with (application) | Wide variety of dissolved oxygen samples using polarographic DO electrode |
|---|
| Measurement Modes | Dissolved Oxygen (mg/L with Temperature and Barometric Pressure), Dissolved Oxygen (ppm with Temperature and Barometric Pressure), Dissolved Oxygen (% Saturation with Temperature and Barometric Pressure) |
|---|
| Sensor types | Polarographic Dissolved Oxygen Sensor |
|---|
| Range (OD by polarographic measurement) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Resolution (OD by polarographic measure) | 0.1. 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Accuracy (OD by polarographic measurement) | ±2% saturation; ±0.02 mg/L or ppm |
|---|
| Pressure range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
|---|
| Calibration modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
|---|
| Temperature range (metric) | -30.0°C to +130.0°C |
|---|
| Resolution (temperature) | 0.1°C, 0.1°F |
|---|
| Accuracy (temperature) | ±0.3°C, ±0.5°F |
|---|
| Temperature selection | Automatic with ATC temperature sensor, ambient or manual |
|---|
| Calibration of the temperature sensor | 1 or 2 point temperature offset calibration |
|---|
| Display type | 7-in. High-resolution Color Graphic LCD |
|---|
| Backlight option | Yes |
|---|
| Memory | Non-volatile |
|---|
| Data points | 10,000 with Date and Time Stamp |
|---|
| Type of function d | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
|---|
| Alarm outputs | Calibration reminder alarm, high and low limit alarm per parameter |
|---|
| Entry | 9-pin MiniDIN for dissolved oxygen with ATC |
|---|
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
|---|
| IP Index | IP54 |
|---|
| Mains adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
|---|
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
|---|
| Weight (metric) | 1.00 kg |
|---|
| Weight (imperial) | 2.20 lbs. |
|---|
| Relative humidity range | 5 to 85%, non-condensing |
|---|
| Warranty | 2 year meter warranty |
|---|
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
|---|
| Keyboard | Capacitive touchscreen user interface |
|---|
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
|---|
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
|---|
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Methods | 10 |
|---|
| Model | DO213 |
|---|
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
|---|
| Percent Saturation Resolution (POLAROGRATIC DO) | 0.1, 1% saturation |
|---|
| Percentage saturation range (RDO) | 0.0 to 600.0% saturation |
|---|
| Percent Saturation Relative Accuracy (POlarographic DO) | ±2% saturation |
|---|
| Saturation coefficient resolution (RDO) | 0.1, 1% saturation |
|---|
| Type of probe | Polarographic or optical DO electrode |
|---|
| Range (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Resolution (OD) | 0.1. 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Channels | 1 |
|---|
| Resolution (RDO) | 0.1. 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Salinity factor | 0.0 to 50.0 ppt |
|---|
| Type | DO Bench Meter Standard Kit |
|---|
| Accuracy (barometer) | ±6.0 mmHg; ±0.008 bar |
|---|
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |