TaqMan® Determination of Genetic Expression VIC TaqMan™

Ref.: BL-RE-071045
€560.00 excl. VAT

Applied Biosystems TaqMan Gene Expression assays, VIC, are used for quantitative real-time PCR analysis of gene expression and consist of a pair of unlabeled PCR primers and a TaqMan probe with a dye label (VIC) on the 5' end and a minor groove binder (MGB) and nonfluorescent quencher (NFQ) on the 3' end.

Supplier ref.: 11957021

Method of detection
Primer-probe
Format
Tube
GC-Rich PCR Performance
Haut
PCR method
qPCR
Reaction speed
Fast
Brand
TaqMan

The Applied Biosystems TaqMan, VIC, gene expression tests are used for the quantitative analysis of gene expression by PCR in real time; they consist of an unmarked PCR primer couple and a single gene expression...

The gene expression tests Applied Biosystems TaqMan, VIC, are used for the quantitative analysis of gene expression by PCR in real time; they consist of an unmarked PCR primer couple and a TaqMan sensor with a dye (VIC) in 5 and a small furrow ligand (MGB) and a non-fluorescent fire extinguisher (NFQ) in 3

Pre-formulated test
• 2 unmarked PCR primers (900 nM each, final concentration 1X)
• 1 TaqMan MGB probe marked with VIC dye (final concentration 1X of 250 nM).

TaqMan gene expression tests are the absolute reference for real-time PCR gene expression studies, which have been carried out over 20 years of experience. Each test includes target primers and a specific sequence probe, optimized to deliver the best functional performance. No additional fusion curve design, optimization or analysis is required. Available in many formats and for many species, new tests are constantly added to meet your research needs. TaqMan tests have been cited in more than 40,000 publications and are protected by over 350 patents.

Formulation

Concentration: 60X.

Compatibility

Designed for use with: 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7...

Detection

Method of detection: Abortion-sound.

Number of reactions

Sufficient for 750 reactions.

Format

Format : tube.

Technical specifications

General
BrandTaqMan
Supplier ref. (Fisher Scientific)11957021
Specifications
Method of detectionPrimer-probe
FormatTube
GC-Rich PCR PerformanceHaut
PCR methodqPCR
Reaction speedFast
For use with (equipment)7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex
Ecological conceptDurable packaging
Product typeDetermination of genetic expression
Concentration60X
Fidelity (vs. Taq)60 X
No. of reactions750 reactions
A question or a specific configuration?
Contact us for a quote.

Supplier ref.: 11957021