Applied Biosystems™ Detection Activator, for real-time PCR: The Detection Enhancer has a unique formulation designed to improve matrice amplification in real-time PCR workflows (qPCR). This reagent is...
Applied Biosystems™ Detection Activator, for real-time PCR: The Detection Enhancer has a unique formulation designed to improve matrice amplification in real-time PCR workflows (qPCR). This reagent is...
- The Enhanced Detection is specifically formulated for qPCR amplification of particularly stable d的DNA sequences. It is only intended for real-time PCR workflows in which amplification is affected by GC-rich matrices and/or with persistent secondary structures. These reagents may affect sensitivity to other types of targets, so it is recommended that the reaction be prepared first without Detection Enhancer. If no signal is observed for samples that are supposed to be positive, then add the Enhanced Detection to the reaction.
- The recommended volume of Detection Enhancer by reaction of 25 μL is 1.67 μL. For more information on the applications of the Enhanced Detection, see the AgPath-ID One-Step RT-qPCR Reagents Kit User Guide
The Enhanced Detection presents a formulation...
The Enhanced Detection has a unique formulation to improve matrice amplification in real-time PCR (qPCR) workflows. This reagent is particularly useful for samples...
Improves qPCR amplification of matrices to...
Improved qPCR amplification of high GC and persistent secondary structure matrices
Compatible with any masterbatch of PCR...
Compatible with any real-time PCR master mixture Applied Biosystem
Different kit formats suitable for all types of...
Different kit formats adapted to all laboratory cadences
The GC-rich sequences of d-DNA are...
The GC-rich d-DNA sequences are generally defined as those containing >60 % cytosine (C) or guanine (G). Samples rich in GC can be particularly difficult to amplify, as these samples are...
Technical specifications
| General |
| Brand | Applied Biodiversitys |
| Supplier ref. (Fisher Scientific) | 30057791 |
| Specifications |
| Method of detection | Primer-probe |
| GC-Rich PCR Performance | High |
| PCR method | 1-step RT-qPCR |
| Reaction speed | Standard |
| For use with (equipment) | 7500 System |
| Product range | Applied Biosystems |
| Product type | Detection Enhancer |
| For use with (application) | Real-time PCR (qPCR) |
| No. of reactions | 500 reactions of 25 μL |
| Type of sample | Viral samples |
| Physical characteristics |
| Volume | 1.2 mL |
| Storage and shipping |
| Content and storage | 1 x 1.2 mL detection amplifier, store between -5 and -30°C |
| Shipping conditions | Dry Ice |
Origin and customs
| Manufacturer ref. | A44941 |
|---|
| Country of origin | United States |
|---|
| HS customs code | 2924 19 00 00 |
|---|
A question or a specific configuration?