Molecular Probes™ Dose kit MitoProbe™ JC-1

Ref.: BL-RE-088506 1 kit
€860.00 excl. VAT

MitoProbe™ JC-1 dosing kit

Supplier ref.: 10226762

Content and storage
Contient 5 flacons de JC-1 (5′,6,6′-tétrachloro-1,1′,3,3′-tétraéthylbenzimidazolylcarbocyanine iodure) (30 µg / flacon de colorant en poudre), 1 flacon de DMSO (1,5 ml), 1 flacon de CCCP (125 µl, 50 mM dans du DMSO) et 1 flacon de solution saline tamponnée au phosphate 10X (25 ml).

Stocké entre 2 et 8°C. Conserver à l’abri de la lumière.
Method of detection
Fluorescent
Format
Tube
Excitation / emission
514 ⁄ 529, 590
Flow cytometer laser beams
488
Brand
Molecular Probes

The MitoProbe™ JC-1 dosing kit is a fast and reliable test used to detect changes in mitochondria by flow cytometry.

The MitoProbe™ JC-1 dosing kit is a fast and reliable test used to detect changes in mitochondria by flow cytometry.

The permeating membrane dye JC-1 is widely used in the studies of apoptosis to monitor the health of mitochondria. The JC-1 dye shows a potential-dependent accumulation of mitochondria, indicated by a slide of fluorescence emission from green (about 529 nm) to red (about 590 nm). Therefore, mitochondrial depolarization is indicated by a decrease in the ratio of intensity of red/green fluorescence. The potential-sensitive colour change is due to the formation dependent on the concentration of fluorescent red J-aggregates.

Unlike other mitochondrial dyes that are affected by the potential of the plasma membrane, the ratio of green to red fluorescence of JC-1 depends solely on the potential of the membrane and not on other factors such as dimension, form and mitochondrial density, which can influence fluorescence signals at a single component. Using fluorescence ratio detection allows researchers to make comparative measurements of membrane potential and determine the percentage of mitochondria within a population that reacts to an applied stimulus.

Marking

Marker: JC-1.

Compatibility

Designed for use with: Stream Cytometer.

Applications

Streaming cytometry.

MitoProbe™ range

It is part of the MitoProbe™ range.

Packaging

Packaging: 1 kit.

Technical specifications

General
BrandMolecular Probes
Supplier ref. (Fisher Scientific)10226762
Specifications
Method of detectionFluorescent
FormatTube
Excitation / emission514 ⁄ 529, 590
Flow cytometer laser beams488
For use with (application)Flow Cytometry
For use with (equipment)Flow meters
Marker or dyeJC-1
No. of reactions100
Product typeJC-1 dosing kit
Product rangeMitoProbe™
Quantity1 kit
Subcellular locationMitochondria
Storage and shipping
Content and storageContains 5 vials of JC-1 (5′,6.6′-tetrachloro-1.1′,3.3′-tetraethylbenzimidazolcarbocyanin iodide) (30 µg/powder colourant vial), 1 vial of DMSO (1.5 ml), 1 vial of CCCP (125 µl, 50 mM in DMSO) and 1 vial of 10X phosphate buffered saline solution (25 ml). Stored between 2 and 8°C. Keep in the dark.
Shipping conditionsAmbient temperature
A question or a specific configuration?
Contact us for a quote.

Supplier ref.: 10226762