Thermo Scientific™ LightShift™ Chemiluminescent RNA EMSA Kit

Ref.: BL-RE-089743
€762.00 excl. VAT

Study RNA-proteins interactions with this non-radioactive EMSA kit for gel delay assays.

Supplier ref.: 10780910

Dose
EMSA strength
Content and storage
Suffisant pour : 100 réactions de liaison et détection sur 1 000 cm2 de membrane (10 mini-gels)• 125 nM contrôle de l’ARN IRE biotinylés 35 µl (stockage à -20°C)
• 10 µM contrôle de l’ARN IRE non marqué, 25 µl (stockage à -20°C)
• 2 mg / ml extrait de foie cytosolique, 50 µl (stockage à -20°C)
• ARNt 10 mg / ml, 100µl (stockage à -20°C)
• Tampon de liaison REMSA 10X, 1 ml (stockage à -20°C)
• 50 % de glycérol, 500 µl (stockage à -20°C)
• Kcl 2 M, 500 µl (à -20°C)
• MgCl2 1 M, 500 µl (à -20°C)
• DTT, lyophilisé (stockage à -20°C)
• Eau sans nucléase, 1,5 ml (stockage à -20°C)
• Tampon de chargement 5X REMSA, 1 ml (stockage à -20°C)
• Streptavidine-HRP stabilisée, 1,5 ml (stockage à 4°C)
• solution Luminol / séquence activatrice, 80 ml (stockage à 4°C
Method of detection
Chemiluminescence
Format
Kit
Type of sample
Protein
Brand
Thermo Scientific

The EMSA kit of RNA chemiluminescent LightShift Thermo Scientific™ provides a non-radioactive solution for the study of RNA-proteins interactions using electrophoretic mobility analysis (EMSA).

The EMSA kit of RNA chemiluminescent LightShift Thermo Scientific™ provides a non-radioactive solution for the study of RNA-proteins interactions using electrophoretic mobility analysis (EMSA).

The RNA EMSA kit uses biotinylated d-RNA probes and a chemiluminescent substrate system to obtain a fast and safe detection of RNA-proteins complexes with sensitivity equivalent to traditional 32P-isotopiques methods. The complete kit is supplied with all the reagents necessary to set up and optimize protein-RNA bonding conditions, positive control of protein-RNA interactions and reagents for chemiluminescent detection of nucleic acid interaction.

Key points: Sensitive: Sensitive chemiluminescence detection comparable to radioactive detection Time saving – to develop radiographic films after exposures of 1 to 5 minutes, against 16-hour exposures required with flexible radioactive systems – compatible with biotinylated d-RNA probes by different methods Easy to use – The complete kit includes optimized reagents for binding reactions and detection of non-radioactive d-RNA probes – eliminates waste problems from radioactive d-RNA probes.

Samples

Type of sample: Protein.

Compatibility

Designed for use with: myECL™ imaging system, radiographic film.

LightShift™ range

It is part of the LightShift™ range.

Technical specifications

General
BrandThermo Scientific
Supplier ref. (Fisher Scientific)10780910
Specifications
DoseEMSA strength
Method of detectionChemiluminescence
FormatKit
Type of sampleProtein
For use with (equipment)myECL™ imaging system, radiographic film
No. of reactions100
Product rangeLightShift™
Product typeKit EMSA ofARN chemiluminescent LightShift
Target specificityNon-target specific
TechnicalImproved chemiluminescence, membrane transfer, gel delay
Storage and shipping
Content and storageSufficient for: 100 binding reactions and detection over 1.000 cm2 membrane (10 mini-gels)• 125 nM control of biotinyl RNA 35 µl (stored at -20°C)• 10 µM control of unlabelled RNA IRE, 25 µl (stored at -20°C)• 2 mg/ml cytosolic liver extract, 50 µl (stored at -20°C)• tRNA 10 mg/ml, 100µl (stored at -20°C) • Binding stamp REMSA 10X, 1 ml (storage at -20°C)• 50% glycerol, 500 µl (storage at -20°C) • Kcl 2 M, 500 µl (storage at -20°C) • MgCl2 1 M, 500 µl (storage at -20°C) • DTT, lyophilized (storage at -20°C)• Water without nuclease, 1.5 ml (storage at -20°C)• Loading stamp 5X REMSA, 1 ml (storage at -20°C)• Streptavidine-HRP stabilized, 1.5 ml (storage at 4°C)• Luminol / Activator sequence solution, 80 ml (storage at 4°C)
A question or a specific configuration?
Contact us for a quote.

Supplier ref.: 10780910