Invitrogen™ mRNA Catcher™ PLUS Purification Kit

Ref.: BL-RE-089947Manufacturer ref.: K157002 96 preparations
€498.00 excl. VAT

The mRNA Catcher™ PLUS kit allows high-speed purification of the mRNA from cells, tissues, blood and total RNA in 96 well formats. By taking advantage of the locked nucleic acid (LNA) technology, the mRNA Catcher...

Content and storage
• 1 plate mRNA Picker PLUS at 96 wells; store at 4°C
• 4 ml of 2X L20 lysis buffer; room temperature
• 30 ml wash pad W15; room temperature
• 4 ml dilution buffer DL1; ambient temperature
• 8 ml de tampon d’élution E3 (eau exempte de RNase traitée par DEPC) ; température ambiante
• 100 µl 0,5M DTT ; température ambiante
Isolation Technology
Affinity Oligo dT
Purification time
1.5 hours (including homogenization of samples)
Volume of discharge
80 μlitres
Type of sample
Cells, tissues, total RNA, total blood, tissues (mammal), total RNA, total blood
Brand
Invitrogen

The mRNA Catcher™ PLUS kit allows high-speed purification of the mRNA from cells, tissues, blood and total RNA in 96 well formats. By taking advantage of the locked nucleic acid (LNA) technology, the mRNA Catcher...

The mRNA Catcher™ PLUS kit allows high-speed purification of the mRNA from cells, tissues, blood and total RNA in 96 well formats. By taking advantage of locked nucleic acid (LNA) technology, the mRNA Catcher PLUS kit offers improved performance and faster protocol, while preserving the efficiency and purity of the mRNA.

The mRNA of the total RNA, cells, tissues and blood samples is hybridized into a immobilized, single-catenary LNA containing 20-mer oligoline (dT). Incorporation of LNA into the oligosol probe increases efficiency and specificity of the hybridization of the binding of l的mRNA. The mRNA can be elected or inversely transcribed to cDNA directly into the well. The mRNA Catcher PLUS method does not require centrifugation, precipitation, phase separation or column filtration. In addition, the complete method can be automated for streamlined high-speed expression profiling for large-scale processes. Insulated L的mRNA is suitable for use in downstream applications such as RT-PCR and RT-qPCR.

Automated purification of nucleic acids, automated isolation of micro-RNA, purification and analysis of the DNA and the RNA, extraction of RNA, isolation of mRNA

Ordering information

Shipping conditions: Wet ice

Automated, high-speed compatible protocols

Automated, high-speed compatible protocols

Robust performance

High connection capacity per well (> 80 ng/well)

Reproducible results

Low CV of well wells and plate plated wells (-2%)

Optimized protocols

For small samples (100 cells, 4 mg tissue and 40 μl blood)

Design of compatible plates

Can be used with most PCR thermocyclers

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)10594823
Specifications
Isolation TechnologyAffinity Oligo dT
Purification time1.5 hours (including homogenization of samples)
Type of sampleCells, tissues, total RNA, total blood, tissues (mammal), total RNA, total blood
End product typemRNA
High-throughput compatibilityHigh-throughput compatible
For use with (equipment)Robotic liquid handling systems
For use with (application)RT-PCR, qPCR, library construction d-cDNA, microarray analysis
Quantity96 preparations
Quantity of start-up equipmentCells: 100 to 106
Woven fabrics: 4 to 40 mg
Total RNA: 0.1 to 100 μg
Total blood: 40 μlitres
Yield>80 ng
Physical characteristics
Volume of discharge80 μlitres
Storage and shipping
Content and storage• 1 plate mRNA Picker PLUS at 96 wells; store at 4°C
• 4 ml of 2X L20 lysis buffer; room temperature
• 30 ml wash pad W15; room temperature
• 4 ml dilution buffer DL1; ambient temperature
• 8 ml of E3 elution buffer (water free of RNase trei
Shipping conditionsAmbient temperature

Origin and customs

Manufacturer ref.K157002
Country of originUnited States
HS customs code3822 90 00 00
A question or a specific configuration?
Contact us for a quote.