The human plasminogen 1 (Hu PI1) inhibitor1 (L-ELISA) quantifies Hu PAI1 in human serum, plasma, buffered solution or cell culture medium. The dosage will recognize only natural human PAI1 and human...
The human plasminogen 1 (Hu PI1) inhibitor1 (L-ELISA) quantifies Hu PAI1 in human serum, plasma, buffered solution or cell culture medium. The dosage will recognize only natural and recombinant human PAI1. Principle of the solid phase L-ELISA human PAI1 sandwich (immuno-enzymatic test) method is designed to measure the amount of the target bound between a pair of matched antibodies. A target-specific antibody was pre-assembled in the wells of the supplied microplate. Samples, standards or controls are then added to these wells and bind to the immobilized antibody (capture). The sandwich is formed by adding the second antibody (detector), a substrate solution that reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this coloured product is directly proportional to the concentration of TP (p) present in the original sample. Rigorous validation Each batch manufactured from this ELISA kit is tested for quality for criteria such as sensitivity, specificity, accuracy and batch-to-batch consistency. See the product manual for more information on validation.
PAI1 (plasminogen 1 activator inhibitor) belongs to the superfamily of serine protease inhibitor and is the main inhibitor of tissue-type and urokinase-type plasminogen activators (tPA and uPA). Platelets are the main source of circulating PAI11, but are synthesized and secreted by many types of tissues and cells, including fibroblasts, smooth muscle cells, endothelial cells, hepatocytes and inflammatory cells. The expression of PAI11 can be regulated at the transcriptional level by many factors, including growth factors, cytokines, hormones, inflammatory factors, glucose or lipid metabolites, vascular tone control factors, chemicals, and other environmental or physical factors. IAP1 is present at increased levels in various disease states, and has been associated with an increase in the occurrence of thrombosis in obesity, thrombophilia and metabolic syndrome. IAP-1 defects are characterized by abnormal bleeding. PAI1 media inhibition of fibrinolysis by inhibiting the activity of plasminogenic activator and may promote neuronal survival. Other PAI1 defects are the cause of a deficiency in plasminogen 1 (PAI-1 deficiency) inhibitor. Alternative isoform epistic transcription variants of PAI1 have also been found. Order information
Shipping conditions: Ambient temperature
Measurement range
Dose range: 31.2-2000 pg/ml.
Duration of dosing
Total dosage duration: 5 hours.
Reproducibility
Coefficient of intradose variation 4.3%, interdose 7.7%.
Samples
Sample type: Serum, Surnatant, Surnatant (plasma volume, 100 μl; serum, 100 μl; supernatant, 100 μl).
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 10083814 |
| Specifications |
| Accession number | P05121 |
| Dose range | 31.2-2000 pg/ml |
| Sensitivity of the dosage | <30 pg/ml |
| Conjugate | Biotin |
| Product type | Kit ELISA |
| Type of sample | Serum, Surnatant, Surnatant |
| Target species | Human |
| For use with (application) | Colorimetric detection |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | 5054 |
| Gene symbol(s) | PAI,PAI-1,PAI1,PLANH1 |
| Incubation time | 5 h |
| Coefficient of inter-dose variation | 7.7% |
| Coefficient of intra-dose variation | 4.3% |
| Contents of kits | 96-well pre-coated plate, Streptavidine HRP, HRP diluent, Wash pad, Chromogen, Stop solution, Adhesive plate covers |
| Marker or dye | HRP |
| Genetic marker | PAI-1 |
| Quantity | 96 tests |
| Regulatory status | RUO |
| Target | Human |
| Test time | 1 h 20 min |
| Physical characteristics |
| Volume of sample | Plasma, 100 μl; serum, 100 μl; supernatant, 100 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 5 h |
Origin and customs
| Manufacturer ref. | KHC3071 |
|---|
| Country of origin | Autriche |
|---|
| HS customs code | 3002 15 00 00 |
|---|
A question or a specific configuration?