Invitrogen™ SDF-1 alpha/CXCL12A Human ELISA Kit

Ref.: BL-RE-090947Manufacturer ref.: EHCXCL12A 1Â kit
€736.00 excl. VAT

The Human SDF-1alpha/CXCL12A (SDF-1?) ELISA quantitates Hu SDF-1? in human serum,plasma,or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu SDF-1?. Principle of the method The Human SDF-1? solid-phase…

Accession number
P48061
Dose range
93.75-6000 pg/ml
Sensitivity of the dosage
80 pg/ml
Calibration range
80 pg/ml to 6000 pg/ml
Description
Kit ELISA SDF-1a (CXCL12A), 96 assays, 1 kit, human species, HRP conjugate, colorimetric detection method, immuno-enzymatic test designed for the quantification and detection of SDF-1a (CXCL12A) in samples using a microplate reader
Brand
Invitrogen

The Human SDF-1alpha/CXCL12A (SDF-1?) ELISA quantitates Hu SDF-1? in human serum,plasma,or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu SDF-1?. Principle of the method The Human SDF-1? solid-phase…

The Human SDF-1alpha/CXCL12A (SDF-1?) ELISA quantitates Hu SDF-1? in human serum,plasma,or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu SDF-1?. Principle of the method The Human SDF-1? solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples,standards,or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the addition of the second (detector) antibody,a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity,specificity,precision,and lot-to-lot consistency. See manual for more information on validation.

CXCL12 is an alpha-chemiokin derived from a stromale cell that is a member of the intercrine family. This genetic product and its CXCR4 receptor can activate lymphocytes and have been involved in metastasis of certain cancers such as breast cancer. Mutations of this gene are associated with resistance to human immunodeficiency virus type 1 infections. Several transcription variants coding different isoforms were found for this gene.

Sensitivity

Sensitivity of dosage: 80 pg/ml.

Measurement range

Dose range: 93.75-6000 pg/ml.

Duration of dosing

Total duration of dosing: 4 h 45 min.

Reproducibility

Intradose variation coefficient < 10%, interdose < 12%.

Target

Target: Human.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)15424963
Specifications
Accession numberP48061
Dose range93.75-6000 pg/ml
Sensitivity of the dosage80 pg/ml
Calibration range80 pg/ml to 6000 pg/ml
DescriptionKit ELISA SDF-1a (CXCL12A), 96 assays, 1 kit, human species, HRP conjugate, colorimetric detection method, immuno-enzymatic test designed for the quantification and detection of SDF-1a (CXCL12A) in samples using a microplate reader
Detectable substances to be analysedSDF-1a (CXCL12A), human SDF-1a
DoseELISA solid-phase sandwich
ConjugateBiotin
Method of detectionColorimetric
Product typeKit ELISA
Protein familyChemiokine & receptors
Type of sampleSerum, Surnatant, Surnatant
SpecificityThis ELISA kit shows no cross-reactivity with the cytokines tested: human angiogenin, BDNF, BLC, ENA-78, FGF-4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF, GM-CSF, IFN-gamma, leptine, MCP-1, MCP
Sufficient for96 dosages
Target speciesHuman
For use with (application)ELISA, protein dosage, protein biology, cancerology, immunology, neuroscience, neurobiology, protein detection, protein analyses
For use with (equipment)Colorimetric microplate reader
Genetic identification (Enter)6387
Gene symbol(s)IRH,PBSF,SCYB12,SDF1,TLSF,TPAR1
Host speciesHuman
Coefficient of inter-dose variation< 12 %
Coefficient of intra-dose variation< 10 %
Contents of kits96-well pre-coated plate, Standard, Dose diluent concentrate, Biotinylated detection antibody, Wash pad, Chromogen, Stop solution, Adhesive plate covers, 96-well pre-loaded anti-human SDF-1a plate, recombinant lyophilized human SDF-1a standard, t
Marker or dyeHRP
Quantity1Â kit
Regulatory statusRUO
Research disciplinesSignal transduction
SynonymIRH, PBSF, SCYB12, SDF1, TLSF, TPAR1
TargetHuman
Test time1 h 20 min
Physical characteristics
Volume of samplePlasma, 50 μl; serum, 50 μl; supernatant, 100 μl
Storage and shipping
Storage conditions2°C to 8°C
Total duration of dosing4 h 45 min

Origin and customs

Manufacturer ref.EHCXCL12A
Country of originUnited States
HS customs code3002 15 00 00
A question or a specific configuration?