Thermo Scientific™ Nitrate Electrodes Orion™, None, ISE Measuring Devices
Ref.: BL-EQ-911390Manufacturer ref.: 970701
€328.00 excl. VAT
Thermo Scientific™ Orion 9307BNWP and Orion 9707BNWP ionplus nitrate electrodes simply measure nitrate in aqueous solutions precisely and economically.
Brand
Thermo Scientific
Reference
970701
Brand
Thermo Scientific
Thermo Scientific™ Orion 9307BNWP and Orion 9707BNWP ionplus nitrate electrodes simply measure nitrate in aqueous solutions precisely and economically.
Perform fast, simple, accurate and cost-effective measurements of nitrates in aqueous solutions using Thermo Scientific™ Orion™ nitrate electrodes.L-electrode 9707BNWP is a combination electrode with a Sure-Flow™ junction. While conventional electrode junctions are closed, the Sure-Flow junction can be opened and cleaned by rinsing, with a simple pressure on the cap. For use with module 970701.L-Electrode with half-cell for nitrate 9307BNWP (delivered with half-cell module 930702) must be used with reference electrode with double-switch Sure-Flow Orion 900200.
Features L-electrode 9707BNWP is a...
Features L-electrode 9707BNWP is a combined electrode with a Sure-Flow™ junction. As conventional electrode junctions close, the Sure-Flow junction can be opened and cleaned in a clean...
Robustness and maintenance
While conventional electrode junctions are closed, the Sure-Flow junction can be opened and cleaned by rinsing, with a simple pressure on the cap.
Versatility and compatibility
For use with module 970701.L-Electrode with half-cell for nitrate 9307BNWP (delivered with half-cell module 930702) must be used with reference electrode with double-switch Sure-Flow Orion 900200.
Features
The electrode for nitrate ThermoFisher Orion complies with SM 4500-NO3 - D; Orion Method 601 for drinking water and SM 4500-NO3 - D for waste water measurements.
Features L-electrode 9707BNWP is a combined electrode with a Sure-Flow™ junction. While conventional electrode junctions are closed, the Sure-Flow junction can be opened and cleaned by rinsing, with a simple pressure on the cap. For use with module 970701. The half-cell electrode for nitrate 9307BNWP (delivered with the half-cell module 930702) shall be used with the reference electrode with the double-connection Sure-Flow Orion 900200. Required solutions Standards 920706 Nitrate calibration standard 0.1 M NaNO3 920707 Nitrate calibration standard 1000 ppm N 930707 Nitrate calibration standard 100 ppm N ISA 930711 ISA for nitrate measurements, 475 ml vial 930710 Nitrate interference suppressive solution (NISS), 475 ml vial 900046 Electrode Filling Solution Optimum Result F for electrode, 5 60 ml vials 900002 Internal chamber filler solution for double junction reference electrode, 5 60 ml vials Articles included with 9307BNWP 930702 Series 93 detection module for 9307BNWP. Quantity :2 930711 ISA for nitrate measurements. 1 vial of 60 ml 9707BNWP 970701 Series 97 detection module for 9707BNWP. Quantity: 2 900046 ISA for nitrate measurements. 1 60 ml bottle Warranty period Electrode: 12 months from purchase date Module: 6 months from purchase date and 3 months once in service
Technical specifications
General
Brand
Thermo Scientific
Description
Replacement module for the Nitrate-Sure-Flow combined electrode 9707BNWP; 1/box
Performance
Applications
Water testing, soil, soil extracts and saturated paste, plants and forage, animal feed
Drive
stable and drift-free potentials
Types of connectors
None
For use with (equipment)
ISE measuring apparatus
Junction
The Free Flow Sure-Flow™ junction guarantees stability