Thermo Scientific™ Sodium electrodes Orion™, BNC
Thermo Scientific™ Orion sodium electrodes measure sodium in aqueous solutions quickly, accurately and economically.
- Brand
- Thermo Scientific
- Reference
- 8411BN
- Brand
- Thermo Scientific
Thermo Scientific™ Orion sodium electrodes measure sodium in aqueous solutions quickly, accurately and economically.
Perform fast, accurate and cost-effective sodium measurements in aqueous solutions using Thermo Scientific™ Orion™ sodium electrodes. A single redox internal system with Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, greater stability and greater accuracy than conventional sodium electrodes.
Sodium electrode is commonly used to measure samples such as food, beverages and feed.
900010 Sodium electrode filling solution and ROSS reference solution, 5 vials of 50 ml
For regular sodium measurements (< 10-5 M or 0.2 ppm)
900012 Sodium electrode filling solution and ROSS reference 5 vials of 50 ml Storage solution 841101 Sodium electrode storage solution, 475 ml vial Reconditioning solution for sodium electrodes, 5 vials of 50 ml
| General | |
|---|---|
| Brand | Thermo Scientific |
| Description | Sodium electrode Orion with ROSS half cell |
| Internal reference | 800300 or 800500U |
| Performance | |
| Applications | Sodium measurement in aqueous solutions is fast, accurate and cost-effective; the single internal redox system with ROSS™ electrode provides faster response, stability and accuracy higher than conventional sodium electrodes |
| Diameter (imperial) of the body | 0.47 po |
| Body diameter (metric) | 13 mm |
| Electrode | Half-cell. Use with Orion reference 800500U. |
| Type of filling solution | 900010 or 900012 for low Na+; fill solution for ROSS sodium electrode: 50 ml |
| Length (metric) | 120 mm |
| Length (metric) of cable | 1m |
| Measurement ranges | 1 x 10-6 M saturation0.02 ppm saturation |
| Operating ranges (metric) | Saturation at 10-6 M , saturated at 0.02ppm |
| Parameter | Electrode with selective half-cell of sodium ions |
| Repayable | No |
| Types of connectors | BNC |
| For use with (equipment) | ISE measuring apparatus |
| Junction | Ceramic |
| Temperature (metric) in operation | 0° to 100°C |
| Type | Half-cell Ion Selective Electrode |
| Physical characteristics | |
| Material | Glass body |
| Compliance and warranty | |
| Certifications/Compliance | ASTM D2791, AOAC 976.25, TAPPI T 625. |
| Manufacturer ref. | 8411BN |
|---|---|
| Country of origin | United States |
| HS customs code | 9027 90 00 00 |