| General |
| Brand | Thermo Scientific |
| Model | EC212 |
| Range of TDS factors | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Reference temperature (metric) | 5, 10, 15, 20, 25 or 30°C |
| Range (conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Range (resistivity) | 1.0 Ω to 100.0 MΩ |
| Range (salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Performance |
| Mains adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Precision (conductivity) | ±0.5% reading |
| Accuracy (resistivity) | ±0.5% reading |
| Accuracy (salinity) | ±0.5% reading |
| Accuracy (TDS) | ±0.5% reading |
| Accuracy (temperature) | ±0.3°C, ±0.5 °F |
| Alarm outputs | Calibration reminder alarm, high and low limit alarm per parameter |
| Backlight option | Yes |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Channels | 1 |
| For use with (application) | Meter with stand, purchase electrode for applications separately. Compliant with USP 645, EP 2.2.38, JP 2.51, EPA 120.1, ASTM D1125, Standard Methods 2510B, ISO 7888, USGS Ch. 6.3 |
| Includes | Meter with electrode stand, USB flash drive, computer cable, 100-240V 50/60Hz universal power adapter (purchase electrode separately) |
| Entry | 8-pin MiniDIN for conductivity with ATC |
| Keyboard | Capacitive touchscreen user interface |
| Languages | Chinese |
| Type of function d | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Memory | Non-volatile |
| Methods | 10 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Resolution (conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Resolution (resistivity) | 0.1 minimum, self-angling |
| Resolution (salinity) | 0.001 ppt minimum; 0.01 minimum PSU; gold 0.01% minimum NaCl, self-angling |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Resolution (temperature) | 0,1°C, 0,1°F |
| Methods of measuring salinity | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
| Thermal compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Temperature selection | Automatic with ATC temperature sensor, ambient or manual |
| Type | Paillage conductimeter with support |
| Data points | 10,000 with Date and Time Stamp |
| Display type | 7-in. High-resolution Color Graphic LCD |
| IP Index | IP54 |
| Measurement Modes | TDS with Temperature |
| Temperature range (metric) | –30°C à +130°C |
| Physical characteristics |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Weight (metric) | 1 kg |
| Compliance and warranty |
| Calibration | Conductivity, TDS, Salinity, Temperature |
| Calibration points | 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Calibration points (conductivity) | 1 to 5 points |
| Certifications/Compliance | CE, TUV 3-1, FCC class A |
| Calibration of the temperature sensor | 1 or 2 point temperature offset calibration |
| Warranty | 2 year meter warranty |