| General |
| Brand | Thermo Scientific |
| Model | PC215 kit for pure water |
| Product type | pH/Ion/Conductivity Bench Meter Pure Water Kit |
| Range (specific ions) | 0.0001 to 19999 |
| Range (ion) | 0.0001 to 19999 |
| Range (rH) | -2000 to 2000 mV |
| Range (relative mV) | -2000 to 2000 mV |
| Range of TDS factors | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Reference temperature (metric) | 5, 10, 15, 20, 25 or 30°C |
| Range (conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Range (resistivity) | 1.0 Ω to 100.0 MΩ |
| Range (salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Range (mV) | -2000 to 2000 mV |
| Range (pH) | -2 to 20 |
| Performance |
| Mains adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Precision (conductivity) | ±0.5% reading |
| Clarification (specific ions) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (resistivity) | ±0.5% reading |
| Accuracy (salinity) | ±0.5% reading |
| Accuracy (TDS) | ±0.5% reading |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (pH) | ±0.002 pH |
| Advanced ionometric functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Alarm outputs | Calibration reminder alarm, high and low limit alarm per parameter |
| Backlight option | Yes |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Channels | 2 |
| Data points | 10,000 with Date and Time Stamp |
| For use with (application) | Most common pH samples as well as pH samples containing tris buffers, proteins, sulfides, halides or other components that can interfere with silver-chloride; pure water conductivity samples in the 0.01 to 300 μS/cm range. Compliant with pH methods USP 791, EP 2.2.3, JP 2.54, ASTM 1293, EPA 150.1, EPA 150.2, ISO 10523, Standard Methods 4500-H+, USGS Ch. 6.4; and Conductivity methods USP 645, EP 2.2.38, JP 2.51, EPA 120.1, ASTM D1125, ISO 7888, Standard Methods 2510B, USGS Ch. 6.3 and other pure water conductivity methods. |
| Includes | Meter with stand (PSTAR2150); ROSS Ultra Triode refillable epoxy-body pH/ATC electrode (8157BNUMD); ultra-pure water 2-cell K=0.1 conductivity/ATC electrode with flow cell (013016MD); pH 4.01 and 7.00 buffer pouches; Pure Water pH 4.10, 6.97 and 9.15 buffer bottles; Pure Water pHISA solution; pH electrode storage sleeve and base; 100 μS/cm conductivity standard bottles |
| Entry | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Isopotential point | 7,000 pH; 1000 ion concentration |
| Keyboard | Capacitive touchscreen user interface |
| Languages | Chinese |
| Type of function d | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Memory | Non-volatile |
| Methods | 10 per year (20 total) |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Resolution (conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Resolution (specificions) | 0.0001 minimum, 1 to 5 digits |
| Resolution (ion) | 0.0001 minimum, 1 to 5 digits |
| Resolution (rH) | 0.1 mV |
| Resolution (resistivity) | 0.1 minimum, self-angling |
| Resolution (salinity) | 0.001 ppt minimum; 0.01 minimum PSU; gold 0.01% minimum NaCl, self-angling |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Resolution (mV) | 0.1 mV |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Methods of measuring salinity | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
| Temperature accuracy | ±0,3°C / ±0,5°F |
| Thermal compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Temperature resolution | 0,1°C, 0,1°F |
| Temperature selection | Automatic with ATC temperature sensor, ambient or manual |
| Display type | 7-in. High-resolution Color Graphic LCD |
| IP Index | IP54 |
| Measurement Modes | mV |
| Temperature range (metric) | -30.0°C to +130.0°C |
| Physical characteristics |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Weight (metric) | 1.00 kg |
| Compliance and warranty |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Calibration points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Calibration points (conductivity) | 1 to 5 points |
| Calibration points (ionometry) | Up to 5 |
| Calibration points (pH) | 1 to 5 points |
| Certifications/Compliance | CE, TUV 3-1, FCC class A |
| Calibration of the temperature sensor | 1 or 2 point temperature offset calibration |
| Warranty | 2 year meter warranty |