Thermo Scientific™ Portable Dissolved Oxygen Instrument Orion Star™ A323

Ref.: BL-EQ-911782Manufacturer ref.: STARA3235
€2,111.00 excl. VAT

Monitor dissolved oxygen (optical/polarographic) and temperature accurately with the portable measuring instrument for RDO / OD Thermo Scientific™ Orion™ Star A323 dedicated to difficult field tests.

Brand
Thermo Scientific
Reference
STARA3235
Brand
Thermo Scientific

Monitor dissolved oxygen (optical/polarographic) and temperature accurately with the portable measuring instrument for RDO / OD Thermo Scientific™ Orion™ Star A323 dedicated to difficult field tests.

Enjoy high precision and optimal performance wherever you need it with the dissolved oxygen measuring instrument and the Portable Thermo Scientific™ Orion Star A323, designed for a wide range of dissolved oxygen and temperature tests as well as field applications. Evaluate samples in the most difficult places using this waterproof measuring instrument with an IP67-classed housing. Use an optical RDO probe or polarographic OD probe and perform calibration using water saturated air, air saturated water, a custom value (Winkler) or a zero point. Save up to 5000 sets of data points with time stamping and transfer logs easily to a printer or computer.

Measure dissolved oxygen as a percentage of...

Measure dissolved oxygen as a percentage saturation or mg/l with temperature using OD optical probes RDO Orion or polarographic OD probes Orion

Perform calibration of dissolved oxygen at...

Perform calibration of dissolved oxygen using water saturated air options, air saturated water, custom value (Winkler titration) and zero point

Automatically compensate for...

Automatically compensate dissolved oxygen measurements using ATC temperature, manual salinity capture and an integrated barometer for barometric pressure measurements

A backlit graphic display informative and...

An informative and easy-to-read backlit graphic display with clear screen instructions simplifies the operation

Capture your important measures thanks to...

Capture your important measurements with the stability indicator of the measurements and selectable readable modes: Auto-Read (Auto-Read) maintains a stable reading, Continuous (Continu) indicates...

The timed data log collects and...

The timed data log collects and records up to 5,000 sets of measurements with the sample identifier and the optional user ID

Features

  • Measure dissolved oxygen as a percentage saturation or mg/l with temperature using OD optical probes RDO Orion or polarographic OD probes Orion
  • Perform calibration of dissolved oxygen using water saturated air options, air saturated water, custom value (Winkler titration) and zero point
  • Automatically compensate dissolved oxygen measurements using ATC temperature, manual salinity capture and an integrated barometer for barometric pressure measurements
  • An informative and easy-to-read backlit graphic display with clear screen instructions simplifies the operation
  • Capture your important measurements with the measure stability indicator and selectable readability modes: Auto-Read (Auto-Read) maintains a stable reading, Continuous (Continu) indicates the evolution of the results with a hold option and Timed (Temporized) records the data at specific intervals
  • The timed data log collects and records up to 5,000 sets of measurements with the sample identifier and the optional user ID
  • Calibration log remembers the ten most recent calibrations
  • The non-volatile memory of the measuring instrument guarantees the protection of your data and settings, even when power is cut off
  • Orion Star Com software facilitates data transfers to a computer via USB or RS232 connection
  • Flexible power options with optional AA batteries or universal power adapter
  • The IP67 classed case is waterproof for reliable operation in the field
  • The measuring instrument kits include a rigid transport case and instrument shielding with electrode supports, adjustable wrist strap/belt and integrated instrument support
  • The measuring instruments are CE, TUV 3-in-1 and FCC class A certified and are accompanied by a 3-year warranty for each exchange.

Technical specifications

General
BrandThermo Scientific
DescriptionOrion Star A323 RDO / OD portable measuring instrument set with optical OD RDO sensor, protective shielding and transport case
ModelOrion Star A323 RDO Portable Measuring Instrument / Dissolved Oxygen / Temperature
Pressure range400 to 850 mmHg
Range (OD by polarographic measurement)0.00-90.00mg/L
Range (RDO)0.00 to 50.00mg/L
Relative humidity range5 to 85 %, non-condensing
Performance
Mains adapterUniversal power adapter 50-60 Hz, 100-240 VCA (sold separately, Catalogue No 1010003)
Accuracy (barometer)± 6 mmHg
Accuracy (OD by polarographic measurement)±0.2 mg/l or ±2 per cent of measurement, whichever is higher
Accuracy (RDO)±0.1 mg/l up to 8 mg/l, ±0.2 mg/l from 8 to 20 mg/l, ± 10% of measurement up to 50 mg/l
Accuracy (temperature)± 0.1°C
Alarm outputsHigh/low limit alarm, calibration alarm
Backlight optionYes, selectable
Barometric pressure correction400 to 850 mmHg, automatic using integrated barometer or manual input
Battery life800 hours
Type of batteryFour AA batteries (included)
Channels1
Details of data managementTransfer a single data point, data point range or all data points to the printer or computer
Data points5000 with time stamp
Display typeBacklit LCD graphic screen
IncludesOptical d-OD sensor d-ODR, instrument protection housing and transport case
Entry9 pin Mini-DIN (OD RDO optical or polarographic sensor with integrated temperature)
KeyboardComplete with menu-specific function keys and scroll/double function shortcut keys
LanguagesEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
Type of function dAutomatic data storage with measurement modes Automatic and Temporized reading; manual data storage with Continuous mode
MemoryNon-volatile memory keeps data log, calibration log and measurement instrument parameters
Methods10 per channel with password protection
OutputsUSB, RS232
Percent Saturation Range (POLAROGRAPHIC DO)Saturation from 0.0 to 600.0 %
Percent Saturation Relative Accuracy (RDO)±2 % saturation ≤ 200 % saturation ±10 % saturation > 200 % saturation
Percent Saturation Resolution (POLAROGRATIC DO)0.1, 1 per cent saturation
Percentage saturation range (RDO)Saturation from 0.0 to 500.0 %
Saturation coefficient resolution (RDO)0.1, 1 % saturation
Percent Saturation Relative Accuracy (POlarographic DO)±2 per cent saturation or ±2 per cent measurement, whichever is greater
Pressure resolution1 mmHg
Type of probeOptical dissolved oxygen probe RDO, polarographic dissolved oxygen probe (includes Orion optical OD RDO sensor 087010MD)
Resolution (OD by polarographic measure)0.01, 0.1 mg/l
Resolution (RDO)0.01, 0.1 mg/l
Resolution (temperature)0,1°C (0,1°F)
Salinity factor0.0 to 45.0 ppt, automatic correction via manual sample salinity input
StabilityQuick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable
Temperature (metric) in operation5°C to 45°C (ambient temperature)
Temperature selectionAutomatic with temperature sensor ATC
TypePortable DO Meter
IP IndexIP 67
Measurement ModesOxygen dissolved in % saturation or mg/l with temperature and barometric pressure
Percent Saturation Range Polarographic DOSaturation from 0.0 to 600.0 %
Sensor typesDissolved oxygen sensor optical RDO or dissolved oxygen sensor polarographic
Temperature range (metric)0.0°C to 50.0°C
Physical characteristics
Dimensions (L x W x H)24°cm x 10°cm x 6,5°cm (9,5°in x 3,9°in x 2,6°in.)
Weight (metric)0.5 kg
Electrical
Power supply4 AA batteries (included) or universal power adapter (sold separately)
Compliance and warranty
Calibration modesAir saturated with water, air saturated water, manual (Winkler titration), zero point
Certifications/ComplianceCE, TUV 3-1, FCC class A
Calibration of the temperature sensorTemperature calibration in 1 point
Warranty3-year warranty for measuring instruments

Origin and customs

Manufacturer ref.STARA3235
Country of originIndonésie
HS customs code9027 89 90 00
A question or a specific configuration?
Contact us for a quote.