Thermo Scientific™ Portable multimeter for pH / ISE / conductivity / dissolved oxygen Orion Star™ A329

Ref.: BL-EQ-911790Manufacturer ref.: STARA3295
€3,106.00 excl. VAT

Measure pH, ion concentration, conductivity, dissolved oxygen and temperature accurately using portable pH/ISE/conductivity measuring instrument / RDO/OD Scientific™ Orion™ Star A329329

Brand
Thermo Scientific
Reference
STARA3295
Brand
Thermo Scientific

Measure pH, ion concentration, conductivity, dissolved oxygen and temperature accurately using portable pH/ISE/conductivity measuring instrument / RDO/OD Scientific™ Orion™ Star A329329

Enjoy high precision and optimal performance wherever you need it thanks to the portable multimeter for pH, ISE, conductivity, OD and RDO Thermo Scientific™ Orion™ Star A329, designed for a wide range of pH, ionic concentration, conductivity, dissolved oxygen and temperature tests, as well as field applications. Evaluate samples in the most demanding locations using this waterproof measuring device with an IP67 housing. Use the three channels to measure pH, conductivity and l-OD simultaneously or view each channel separately. Record up to 5000 sets of data points with time stamping and transfer them to a printer or computer.

A great comfort of use associated with the...

A great comfort of use combined with the benefits of a pH meter / ionometer, a conductimeter and an oxygen measuring instrument dissolved in a simple system to use

Measure pH

Measure pH, ion concentration, mV, relative mV or rH with temperature on the first channel

Easily display individual measurements on...

Easily display individual measurements on a full screen display and quickly switch to a split screen to view multiple measurements simultaneously

Perform up to five pH calibration points...

Perform up to five pH and ISE calibration points with a calibration modification option that allows for individual points to be corrected without complete recalibration

Perform up to five calibration points of the...

Perform up to five calibration points of conductivity

Automatic range conductivity values...

Automatic range conductivity values provide homogeneous measurements over the entire measurement range without needing to recalibrate

Features

  • A great comfort of use combined with the benefits of a pH meter / ionometer, a conductimeter and an oxygen measuring instrument dissolved in a simple system to use
  • Measure pH, ion concentration, mV, relative mV or rH with temperature on the first channel; measure conductivity, TDS, salinity or resistivity with temperature on the second channel and measure dissolved oxygen as a percentage saturation or mg/l with temperature using OD optical RDO probes or polarographic OD probes on the third channel
  • Easily display individual measurements on a full screen display and quickly switch to a split screen to view multiple measurements simultaneously
  • Perform up to five pH and ISE calibration points with a calibration modification option that allows for individual points to be corrected without complete recalibration
  • Perform up to five calibration points of conductivity
  • Automatic range conductivity values provide homogeneous measurements over the entire measurement range without needing to recalibrate
  • Use linear, nonlinear EP (USP) thermal compensation or deactivated conductivity with reference temperatures of 5, 10, 15, 20 or 25 °C
  • Perform calibration of dissolved oxygen using water saturated air options, air saturated water, custom value (Winkler titration) and zero point
  • Automatically compensate dissolved oxygen measurements using ATC temperature, manual salinity capture and an integrated barometer for barometric pressure measurements
  • An informative and easy-to-read backlit graphic display with clear screen instructions simplifies the operation
  • Capture your important measurements with the measure stability indicator and selectable readability modes: Auto-Read (Auto-Read) maintains a stable reading, Continuous (Continu) indicates the evolution of the results with a hold option and Timed (Temporized) records the data at specific intervals
  • The timed data log collects and records up to 5,000 sets of measurements with the sample identifier and the optional user ID
  • Calibration log remembers the ten most recent calibrations
  • The non-volatile memory of the measuring instrument guarantees the protection of your data and settings, even when power is cut off

Technical specifications

General
BrandThermo Scientific
DescriptionPortable pH/ISE/conductivity/OD Orion Star A329 measuring instrument kit with low-maintenance pH/ATC electrode ROSS Ultra Triode, DuraProbe 4-cell conductivity sensor, D-OD optical sensor d-ODR, solutions, protective housing and transport case
ModelpH/ISE/mV/RmV/rH/conductivity/TDS/salinity/resistivity/optical ODR/solved oxygen/temperature Orion Star A329
Pressure range400 to 850 mmHg
Product typePortable measuring instrument kit
Range (specific ions)0.0001 to 19900 with selectable units of ppm, molar mass, mg/l, %, ppb or without unit
Range (rH)± 2000.0 mV
Range (OD by polarographic measurement)0.00-90.00 mg/l
Range (RDO)0.00 to 50.00 mg/l
Range (relative mV)± 2000.0 mV
Relative humidity range5 to 85 % non-condensing
Range of TDS factorsLinear (0.02 to 9.99)
Reference temperature (metric)5, 10, 15, 20, 25°C.
Range (conductivity)0.001 μS/cm to 3000 mS/cm
Range (resistivity)2 ohms to 100.0 meg-ohms
Range (salinity)0.06-80.00 psu, 0.05-42.00 ppt
Range (TDS)0.001 to 200.0 ppm
Range (mV)±2000.0 mV
Range (pH)-2.000 to 20.000
Performance
Mains adapterUniversal power adapter 50-60 Hz, 100-240 VCA (sold separately, Catalogue No 1010003)
Accuracy (barometer)± 6 mmHg
Precision (conductivity)0.5 per cent of reading ±1 digit > 3 μS; 0.5 per cent of reading ±0.01 μS ≤ 3 μS
Clarification (specific ions)± 0.2 mV or ± 0.05 per cent, whichever is higher
Accuracy (OD by polarographic measurement)± 0.2 mg/L or ± 2 per cent of measurement, whichever is higher
Accuracy (RDO)± 0.1 mg/L up to 8 mg/L, ± 0.2 mg/L from 8 to 20 mg/L, ± 10% of measurement up to 50 mg/L
Accuracy (resistivity)0.5 per cent of measurement ±1 digit
Accuracy (salinity)0.5 per cent of measurement ±1 digit
Accuracy (TDS)0.5 per cent of measurement ±1 digit
Accuracy (mV)± 0.2 mV or ± 0.05 per cent, whichever is higher
Accuracy (pH)± 0.002
Advanced ionometric functionsSegmented pent (point to point), automatic nonlinear white correction selectable, low concentration stability
Alarm outputsHigh/low limit alarm, calibration alarm
Backlight optionYes, selectable
Barometric pressure correction400 to 850 mmHg, automatic using integrated barometer or manual input
Battery life800 hours
Type of batteryFour AA batteries (included)
Cell Constant0.001 to 199.9 cm-1
Channels3
Details of data managementTransfer a single data point, data point range or all data points to the printer or computer
Data points5000 with time stamp
IncludesStar A329 pH/ISE/conductivity/RDO/OD with batteries; pH/ATC epoxy electrode filled with 8107UWMMD ROSS gel with 3 meters cable; 013010MD DuraProbe epoxy conductivity probe with 4 probes (K=0.475) with 3 meters cable; OD 087010MD RDO optical probe with 3 meters cable
EntryBNC (pH electrode or rH), pin (reference electrode), 8 pin MiniDIN (conductivity sensor with ATC temperature sensor or integrated temperature sensor), 9 pin MiniDIN (polarographic OD sensor or optical ODR sensor with integrated temperature)
Isopotential pointpH 7.000
KeyboardComplete with menu-specific function keys and scroll/double function shortcut keys
LanguagesEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
Type of function dAutomatic data storage with measurement modes Automatic and Temporized reading; manual data storage with Continuous mode
MemoryNon-volatile memory keeps data log, calibration log and measurement instrument parameters
Methods10 per channel with password protection
OutputsUSB, RS232
Percent Saturation Range (POLAROGRAPHIC DO)Saturation from 0.0 to 600.0 %
Percent Saturation Relative Accuracy (RDO)±2 % saturation ≤ 200 % saturation ±10 % saturation > 200 % saturation
Percent Saturation Resolution (POLAROGRATIC DO)0.1, 1 per cent saturation
Percentage saturation range (RDO)Saturation from 0.0 to 500.0 %
Saturation coefficient resolution (RDO)0.1, 1 % saturation
Percent Saturation Relative Accuracy (POlarographic DO)±2 per cent saturation or ±2 per cent measurement, whichever is greater
Pressure resolution1 mmHg
Resolution (conductivity)Minimum 0.001 μS, automatic selection up to 4 significant digits
Resolution (specificions)Minimum 0.0001, 1 to 3 significant digits (selected by the user)
Resolution (OD by polarographic measure)0.01, 0.1 mg/L
Resolution (RDO)0.01, 0.1 mg/L
Resolution (resistivity)1 ohm or 0.1 meg-ohm, automatic selection
Resolution (salinity)0.01 psu or 0.01 ppt minimum, automatic selection
Resolution (TDS)Minimum 0.001 ppm, automatic selection up to 4 significant digits
Resolution (mV)0.1 mV
Resolution (pH)0.1, 0.01, 0.001 pH
Salinity factor0.0 to 45.0 ppt, automatic correction using conductivity measurement or manual input of sample salinity
Methods of measuring salinitySalt (psu) or natural sea water (ppt)
StabilityQuick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable
Temperature accuracy± 0.1°C
Thermal compensationLinear, nLFn (non-linear ultra-pure water), nLFu (non-linear ultra-pure water), EP (discharge with warning) or shutdown
Temperature (metric) in operation5 to 45°C (ambient temperature)
Temperature resolution0,1°C, 0,1°F
Temperature selectionManual or automatic with temperature sensor ATC
Display typeBacklit LCD graphic screen
IP IndexIP 67
Measurement ModespH, mV, relative mV (RmV) or rH with temperature; conductivity, TDS, salinity or resistivity with t
Temperature range (metric)-5.0°C to +105.0°C
Physical characteristics
Dimensions (L x W x H)24°cm x 10°cm x 6,5°cm (9,5°in x 3,9°in x 2,6°in.)
Weight (metric)0.5 kg
Electrical
Power supply4 AA batteries (included) or universal power adapter (sold separately)
Compliance and warranty
CalibrationpH with calibration modification option, ion concentration (ISE) with calibration modification option, relative mV
Calibration modesAir saturated with water, air saturated water, manual (Winkler titration), zero point
Calibration pointsRelative mV mode (RmV) 1 point, rH mode 1 point
Calibration points (conductivity)Up to 5
Calibration points (ionometry)1 to 5
Calibration points (pH)1 to 5
Certifications/ComplianceCE, TUV 3-1, FCC class A
Calibration of the temperature sensorTemperature calibration in 1 point
Warranty3-year warranty for measuring instruments

Origin and customs

Manufacturer ref.STARA3295
Country of originIndonésie
HS customs code9027 89 30 00
A question or a specific configuration?
Contact us for a quote.