| General |
| Brand | Thermo Scientific |
| Description | Orion Versa Star Pro mat measuring instrument kit with pH/mV module, conductivity/TDS/salinity/resistivity module, pH/ATC epoxy-body electrode ROSS Ultra Triode, 4-cell conductivity sensor DuraProbe, solutions and support |
| Product type | Multimeter kit |
| Range (rH) | ± 2000.0 mV |
| Range (relative mV) | ± 2000.0 mV |
| Relative humidity range | 5 to 85 % non-condensing |
| Range of TDS factors | Linear (0.02 to 9.99) |
| Reference temperature (metric) | 5, 10, 15, 20, 25°C. |
| Range (conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Range (resistivity) | 2 ohms to 100.0 meg-ohms |
| Range (salinity) | 0.06-80.00 psu, 0.05-42.00 ppt |
| Range (TDS) | 0.001 to 200.0 ppm |
| Range (mV) | ±2000.0 mV |
| Range (pH) | -2.000 to 20.000 |
| Performance |
| Mains adapter | Universal power adapter 50-60 Hz, 100-240 VAC (catalogue number STARA-PWR) |
| Precision (conductivity) | 0.5 per cent of reading ±1 digit > 3 μS; 0.5 per cent of reading ±0.01 μS ≤ 3 μS |
| Accuracy (resistivity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (salinity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (TDS) | 0.5 per cent of measurement ±1 digit |
| Accuracy (mV) | ± 0.2 mV or ± 0.05 per cent, whichever is higher |
| Accuracy (pH) | ± 0.002 |
| Alarm outputs | Set-up point alarm, high/low limit alarm, calibration alarm |
| Backlight option | Yes |
| Cell Constant | 0.001 to 199.9 cm-1 |
| Channels | 4 - customizable with modules |
| Details of data management | Transfer a single data point, data point range or all data points to the printer or computer |
| Data points | 2000 with time stamping |
| Includes | Versa Star Pro measuring instrument, pH module VSTAR-PH, conductivity module VSTAR-CND, pH/ATC electrode with epoxy body 8157BNUMD ROSS Ultra Triode, conductivity sensor 013005MD Orion DuraProbe 4-cell (K=0.475), solution kit and buffer pH 810199 ROSS, conductivity standard 011007 Orion 1413 µS, electrode holder, universal power adapter, documentation CD, Quick start guide printed, computer interface cable and test certificate of the measuring instrument. |
| Entry | BNC (pH electrode or rH), pin (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with integrated temperature), two actuator inputs (agitation probe) |
| Isopotential point | pH 7.000 (adjustable) |
| Keyboard | Digital with menu-specific function keys and scroll keys / double function shortcuts |
| Languages | English, French, Italian, German, Chinese, Portuguese and Korean |
| Type of function d | Automatic storage of data with measurement modes Automatic, Timed and Punctual reading; manual storage of data with |
| Memory | Non-volatile memory keeps data log, calibration log and measurement instrument parameters |
| Methods | 10 per channel |
| Outputs | USB (2), RS-232 |
| Resolution (conductivity) | Minimum 0.001 μS, automatic selection up to 4 significant digits |
| Resolution (resistivity) | 1 ohm or 0.1 meg-ohm, automatic selection |
| Resolution (salinity) | 0.01 psu or 0.01 ppt minimum, automatic selection |
| Resolution (TDS) | Minimum 0.001 ppm, automatic selection up to 4 significant digits |
| Resolution (mV) | 0.1 mV |
| Resolution (pH) | 0.1, 0.01, 0.001 pH |
| Methods of measuring salinity | Salt (psu) or natural sea water (ppt) |
| Stability | Quick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable |
| Temperature accuracy | ± 0.1°C |
| Thermal compensation | Linear, nLFn (non-linear ultra-pure water), nLFu (non-linear ultra-pure water), EP (discharge with warning) or shutdown |
| Temperature (metric) in operation | 5 to 45°C (ambient temperature) |
| Temperature resolution | 0,1°C, 0,1°F |
| Temperature selection | Manual or automatic with temperature sensor ATC |
| Display type | Colour LCD graphic display with user-configurable options |
| IP Index | IP 54 |
| Measurement Modes | Resistivity with Temperature |
| Temperature range (metric) | -5.0°C to +105.0°C |
| Physical characteristics |
| Dimensions (L x W x H) | 28 cm x 24 cm x 10 cm (11 in x 9.5 in x 3.9 in), add ≤ 2 cm (0.8 in) of length and height for modules |
| Weight (metric) | 1.2 kg, add 0.2 kg for each module |
| Electrical |
| Nominal power | CC entrance : 9 VCC, 1 A |
| Power supply | Universal sector adapter (included) |
| Compliance and warranty |
| Calibration | pH with calibration modification option, relative mV (RmV), rH, conductivity with calibration modification option |
| Calibration points | Relative mV mode (RmV) 1 point, rH mode 1 point |
| Calibration points (conductivity) | Up to 6 |
| Calibration points (pH) | 1 to 6 |
| Certifications/Compliance | CE, TUV 3-1, FCC class A |
| Calibration of the temperature sensor | Temperature calibration in 1 point |
| Warranty | 3-year warranty for the measuring device and module |