| General |
| Brand | Thermo Scientific |
| Description | Orion Versa Star Pro mat measuring instrument with pH/ISE/mV module, conductivity/TDS module / salinity/resistivity, RDO/DO module and support. |
| Pressure range | 400 to 850 mmHg |
| Product type | Measuring instrument, pH/ISE/mV module |
| Range (specific ions) | 0.0001 to 19990 with selectable units of ppm, molar mass, mg/l, %, ppb or without unit |
| Range (rH) | ± 2000.0 mV |
| Range (OD by polarographic measurement) | 0.00-90.00 mg/l |
| Range (RDO) | 0.00 to 50.00 mg/l |
| Range (relative mV) | ± 2000.0 mV |
| Relative humidity range | 5 to 85%, non-condensing |
| Range of TDS factors | Linear (0.02 to 9.99) |
| Reference temperature (metric) | 5°, 10°, 15°, 20°, 25°C |
| Range (conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Range (resistivity) | 2 ohms to 100.0 meg-ohms |
| Range (salinity) | 0.06-80.00 psu, 0.05-42.00 ppt |
| Range (TDS) | 0.001 to 200.0 ppm |
| Range (mV) | ±2000.0 mV |
| Range (pH) | -2.000 to 20.000 |
| Performance |
| Mains adapter | Universal power adapter 50-60 Hz, 100-240 VAC (catalogue number STARA-PWR) |
| Accuracy (barometer) | ±6 mmHg |
| Precision (conductivity) | 0.5 per cent of the measurement ±1 digit > 3 μS; 0.5 per cent of the measurement ±0.01 μS ≤ 3 μS |
| Clarification (specific ions) | ± 0.2 mV or ± 0.05 per cent, whichever is higher |
| Accuracy (OD by polarographic measurement) | ± 0.2 mg/L or ± 2 per cent of measurement, whichever is higher |
| Accuracy (RDO) | ± 0.1 mg/L up to 8 mg/L, ± 0.2 mg/L from 8 to 20 mg/L, ± 10% of measurement up to 50 mg/L |
| Accuracy (resistivity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (salinity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (TDS) | 0.5 per cent of measurement ±1 digit |
| Accuracy (mV) | ± 0.2 mV or ± 0.05 per cent, whichever is higher |
| Accuracy (pH) | ± 0.002 |
| Advanced ionometric functions | Segmented pent (point to point), automatic nonlinear white correction selectable, low concentration stability |
| Alarm outputs | Set-up point alarm, high/low limit alarm, calibration alarm |
| Backlight option | Yes |
| Barometric pressure correction | 400 to 850 mmHg, automatic using integrated barometer or manual input |
| Cell Constant | 0.001 to 199.9 cm-1 |
| Channels | 4 - customizable with modules |
| Details of data management | Transfer a single data point, data point range or all data points to the printer or computer |
| Data points | 2000 with time stamping |
| Includes | Versa Star Pro measuring device, pH/ISE VSTAR-ISE module, VSTAR-CND conductivity module, RDO/DO VSTAR-RD module, electrode support, universal power adapter, documentation CD, printed Quick Start Guide, computer interface cable and measuring device test certificate. |
| Entry | BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin, 8-pin Mini-DIN (conductivity with temperature sensor), 9-pin Mini-DIN (ODR or OD polarographic with temperature sensor), 2 agitator inputs |
| Isopotential point | pH 7.000 (adjustable), ISE 1.000 (adjustable) |
| Keyboard | Digital with menu-specific function keys and scroll keys / double function shortcuts |
| Languages | English, French, Italian, German, Chinese, Portuguese and Korean |
| Type of function d | Automatic storage of data with measurement modes Automatic, Timed and Punctual reading; manual storage of data with |
| Memory | Non-volatile memory keeps data log, calibration log and measurement instrument parameters |
| Methods | 10 per channel |
| Outputs | USB (2), RS-232 |
| Percent Saturation Range (POLAROGRAPHIC DO) | Saturation from 0.0 to 600.0% |
| Percent Saturation Relative Accuracy (RDO) | ± 2 % saturation ≤ 200 % saturation ± 10 % saturation > 200 % saturation |
| Percent Saturation Resolution (POLAROGRATIC DO) | 0.1, 1 per cent saturation |
| Percentage saturation range (RDO) | Saturation from 0.0 to 500.0 % |
| Saturation coefficient resolution (RDO) | 0.1, 1 per cent saturation |
| Percent Saturation Relative Accuracy (POlarographic DO) | ±2 per cent saturation or ±2 per cent measurement, whichever is greater |
| Pressure resolution | 0.1 mmHg |
| Resolution (conductivity) | Minimum 0.001 μS, automatic selection up to 4 significant digits |
| Resolution (specificions) | Minimum 0.0001, 1 to 4 significant digits (selected by the user) |
| Resolution (OD by polarographic measure) | 0.01, 0.1 mg/L |
| Resolution (RDO) | 0.01, 0.1 mg/L |
| Resolution (resistivity) | 1 ohm or 0.1 meg-ohm, automatic selection |
| Resolution (salinity) | 0.01 psu or 0.01 ppt minimum, automatic selection |
| Resolution (TDS) | Minimum 0.001 ppm, automatic selection up to 4 significant digits |
| Resolution (mV) | 0.1 mV |
| Resolution (pH) | 0.1, 0.01, 0.001 pH |
| Salinity factor | 0.0 to 45.0 ppt, automatic correction using conductivity measurement or manual input of sample salinity |
| Methods of measuring salinity | Salt (psu) or natural sea water (ppt) |
| Stability | Quick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable |
| Temperature accuracy | ± 0.1°C |
| Thermal compensation | Linear, nLFn (non-linear ultra-pure water), nLFu (non-linear ultra-pure water), EP (discharge with warning) or shutdown |
| Temperature (metric) in operation | 5 to 45°C (ambient temperature) |
| Temperature resolution | 0,1°C, 0,1°F |
| Temperature selection | Manual or automatic with temperature sensor ATC |
| Display type | Colour LCD graphic display with user-configurable options |
| IP Index | IP 54 |
| Measurement Modes | Conductivity |
| Temperature range (metric) | -5.0°C to +105.0°C |
| Physical characteristics |
| Dimensions (L x W x H) | 28 cm x 24 cm x 10 cm (11 in x 9.5 in x 3.9 in), add ≤ 2 cm (0.8 in) of length and height for modules |
| Weight (metric) | 1.2 kg, add 0.2 kg for each module |
| Electrical |
| Nominal power | CC entrance : 9 VCC, 1 A |
| Power supply | Universal sector adapter (included) |
| Compliance and warranty |
| Calibration | pH with calibration modification option, ion concentration (ISE) with calibration modification option, relative mV |
| Calibration modes | Air saturated with water, air saturated water, manual (Winkler titration), zero point |
| Calibration points | Relative mV mode (RmV) 1 point, rH mode 1 point |
| Calibration points (conductivity) | Up to 6 |
| Calibration points (ionometry) | 1 to 6 |
| Calibration points (pH) | 1 to 6 |
| Certifications/Compliance | CE, TUV 3-1, FCC class A |
| Calibration of the temperature sensor | Temperature calibration in 1 point |
| Warranty | 3-year warranty for the measuring device and module |