| General |
| Brand | Thermo Scientific |
| Description | Orion Versa Star Pro mat measuring instrument kit with pH/ISE/mV module, conductivity/TDS/salinity/resistivity module, d-ODR/OD module, pH/ATC electrode with epoxy body ROSS Ultra Triode, 4-cell conductivity sensor DuraProbe, optical d-OD sensor d-ODR sensor, agitation probe, solutions and support |
| Pressure range | 400 to 850 mmHg |
| Product type | Multimeter kit |
| Range (specific ions) | 0.0001 to 19990 with selectable units of ppm, molar mass, mg/l, %, ppb or without unit |
| Range (rH) | ± 2000.0 mV |
| Range (OD by polarographic measurement) | 0.00-90.00 mg/l |
| Range (RDO) | 0.00 to 50.00 mg/l |
| Range (relative mV) | ± 2000.0 mV |
| Relative humidity range | 5 to 85%, non-condensing |
| Range of TDS factors | Linear (0.02 to 9.99) |
| Reference temperature (metric) | 5°, 10°, 15°, 20°, 25°C |
| Range (conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Range (resistivity) | 2 ohms to 100.0 meg-ohms |
| Range (salinity) | 0.06-80.00 psu, 0.05-42.00 ppt |
| Range (TDS) | 0.001 to 200.0 ppm |
| Range (mV) | ±2000.0 mV |
| Range (pH) | -2.000 to 20.000 |
| Performance |
| Mains adapter | Universal power adapter 50-60 Hz, 100-240 VCC (catalogue number STARA-PWR) |
| Accuracy (barometer) | ±6 mmHg |
| Precision (conductivity) | 0.5 per cent of the measurement ±1 digit > 3 μS; 0.5 per cent of the measurement ±0.01 μS ≤ 3 μS |
| Clarification (specific ions) | ± 0.2 mV or ± 0.05 per cent, whichever is higher |
| Accuracy (OD by polarographic measurement) | ± 0.2 mg/L or ± 2 per cent of measurement, whichever is higher |
| Accuracy (RDO) | ± 0.1 mg/L up to 8 mg/L, ± 0.2 mg/L from 8 to 20 mg/L, ± 10% of measurement up to 50 mg/L |
| Accuracy (resistivity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (salinity) | 0.5 per cent of measurement ±1 digit |
| Accuracy (TDS) | 0.5 per cent of measurement ±1 digit |
| Accuracy (mV) | ± 0.2 mV or ± 0.05 per cent, whichever is higher |
| Accuracy (pH) | ± 0.002 |
| Advanced ionometric functions | Segmented pent (point to point), automatic nonlinear white correction selectable, low concentration stability |
| Alarm outputs | Set-up point alarm, high/low limit alarm, calibration alarm |
| Backlight option | Yes |
| Barometric pressure correction | 400 to 850 mmHg, automatic using integrated barometer or manual input |
| Cell Constant | 0.001 to 199.9 cm-1 |
| Channels | 4 - customizable with modules |
| Details of data management | Transfer a single data point, data point range or all data points to the printer or computer |
| Data points | 2000 with time stamping |
| Includes | Instrument for measuring Versa Star Pro, pH/ISE VSTAR-ISE module, VSTAR-CND conductivity module, d-ODR/OD VSTAR-RD module, pH/ATC electrode with epoxy body 8157BNUMD ROSS Ultra Triode, 013005MD conductivity sensor Orion DuraProbe 4-cell (K=0.475), optical dissolved oxygen sensor d-ODR 087010MD Orion, 096019Orion Star wave probe, solution kit and buffer pH 810199ROSS, conductivity standard 011007 Orion 1413 μS, electrode support, universal power adapter, documentation CD, printed quick start guide, computer interface cable and measuring instrument test certificate |
| Entry | BNC (pH electrode, rH or selective ions), pin (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with integrated temperature), 9 pin MiniDIN (polarographic OD sensor or optical ODR sensor with integrated temperature), two actuator inputs (agitation probe) |
| Isopotential point | pH 7.000 (adjustable), ISE 1.000 (adjustable) |
| Keyboard | Digital with menu-specific function keys and scroll keys / double function shortcuts |
| Languages | English, French, Italian, German, Chinese, Portuguese and Korean |
| Type of function d | Automatic storage of data with measurement modes Automatic, Timed and Punctual reading; manual storage of data with |
| Memory | Non-volatile memory keeps data log, calibration log and measurement instrument parameters |
| Methods | 10 per channel |
| Outputs | USB (2), RS-232 |
| Percent Saturation Range (POLAROGRAPHIC DO) | Saturation from 0.0 to 600.0% |
| Percent Saturation Relative Accuracy (RDO) | ± 2 % saturation ≤ 200 % saturation ± 10 % saturation > 200 % saturation |
| Percent Saturation Resolution (POLAROGRATIC DO) | 0.1, 1 per cent saturation |
| Percentage saturation range (RDO) | Saturation from 0.0 to 500.0 % |
| Saturation coefficient resolution (RDO) | 0.1, 1 per cent saturation |
| Percent Saturation Relative Accuracy (POlarographic DO) | ±2% saturation or ±2% of measurement, whichever is higher |
| Pressure resolution | 0.1 mmHg |
| Resolution (conductivity) | Minimum 0.001 μS, automatic selection up to 4 significant digits |
| Resolution (specificions) | Minimum 0.0001, 1 to 4 significant digits (selected by the user) |
| Resolution (OD by polarographic measure) | 0.01, 0.1 mg/l |
| Resolution (RDO) | 0.01, 0.1 mg/l |
| Resolution (resistivity) | 1 ohm or 0.1 meg-ohm, automatic selection |
| Resolution (salinity) | 0.01 psu or 0.01 ppt minimum, automatic selection |
| Resolution (TDS) | Minimum 0.001 ppm, automatic selection up to 4 significant digits |
| Resolution (mV) | 0.1 mV |
| Resolution (pH) | 0.1, 0.01, 0.001 pH |
| Salinity factor | 0.0 to 45.0 ppt, automatic correction using conductivity measurement or manual input of sample salinity |
| Methods of measuring salinity | Salt (psu) or natural sea water (ppt) |
| Stability | Quick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable |
| Temperature accuracy | ± 0.1°C |
| Thermal compensation | Linear, nLFn (non-linear ultra-pure water), nLFu (non-linear ultra-pure water), EP (discharge with warning) or shutdown |
| Temperature (metric) in operation | 5 to 45°C (ambient temperature) |
| Temperature resolution | 0,1°C, 0,1°F |
| Temperature selection | Manual or automatic with temperature sensor ATC |
| Display type | Colour LCD graphic display with user-configurable options |
| IP Index | IP 54 |
| Measurement Modes | Relative mV |
| Temperature range (metric) | -5.0°C to +105.0°C |
| Physical characteristics |
| Dimensions (L x W x H) | 28 × 24 × 10 cm (11 × 9.5 × 3.9 in.), add ≤ 2 cm (0.8 in.) of length and height for modules |
| Weight (metric) | 1.2 kg, add 0.2 kg for each module |
| Electrical |
| Nominal power | CC entrance : 9 VCC, 1 A |
| Power supply | Universal sector adapter (included) |
| Compliance and warranty |
| Calibration | pH with calibration modification option, ion concentration (ISE) with calibration modification option, relative mV |
| Calibration modes | Air saturated with water, air saturated water, manual (Winkler titration), zero point |
| Calibration points | Relative mV mode (RmV) 1 point, rH mode 1 point |
| Calibration points (conductivity) | Up to 6 |
| Calibration points (ionometry) | 1 to 6 |
| Calibration points (pH) | 1 to 6 |
| Certifications/Compliance | CE, TUV 3-1, FCC class A |
| Calibration of the temperature sensor | Temperature calibration in 1 point |