Thermo Scientific™ Dissolved Oxygen Module Orion™ VERSA STAR™, 400 to 850 mmHg

Ref.: BL-EQ-911833Manufacturer ref.: VSTAR-RD
€973.00 excl. VAT

Perform numerous applications with the Thermo Scientific™ Orion™ VERSA STAR™ dissolved oxygen module.

Brand
Thermo Scientific
Reference
VSTAR-RD
Brand
Thermo Scientific

Perform numerous applications with the Thermo Scientific™ Orion™ VERSA STAR™ dissolved oxygen module.

Perform numerous applications with the Thermo Scientific™ Orion™ VERSA STAR™ dissolved oxygen module. This versatile dissolved oxygen measuring instrument automatically accepts and recognizes optical or luminescent polarographic and RDO probes. It can be calibrated using a water saturated air method, air saturated water, Winkler titration or zero-point calibration.

Choose from one of the five modules...

Choose from one of the five modules to customize the four channels according to your needs. Its versatility allows you to configure it according to your immediate or subsequent needs.

Non-volatile memory stores up to 2,000...

Non-volatile memory stores up to 2,000 data points with an indication of the time and date.

The measuring instrument compensates the temperature and...

The measuring instrument compensates for temperature and salinity with manual input and barometric pressure (automatic or manual).

Data analysis software for the...

Data analysis software for transferring stored results or displaying measurements in real time is included.

Two USB and RS232 ports facilitate the transfer of...

Two USB and RS232 ports facilitate data transfer and software update.

Direct control for two agitator probes...

Direct control for two Orion Star™ (Ref. 096019, sold separately) allows the samples to be mixed without using agitation plate.

Features

  • Choose from one of the five modules to customize the four channels according to your needs. Its versatility allows you to configure it according to your immediate or subsequent needs.
  • Non-volatile memory stores up to 2,000 data points with an indication of the time and date.
  • The measuring instrument compensates for temperature and salinity with manual input and barometric pressure (automatic or manual).
  • Data analysis software for transferring stored results or displaying measurements in real time is included.
  • Two USB and RS232 ports facilitate data transfer and software update.
  • Direct control for two Orion Star™ (Ref. 096019, sold separately) allows the samples to be mixed without using agitation plate.
  • An included electrode arm and a new design probe support simplify the maintenance and placement of probes in the samples.
  • The included universal power transformer works with almost all AC power sources.
  • The IP54 class case supports splashes.
  • Three-year warranty by exchange of the included measuring instrument.
  • Screen invitations expressed in plain language
  • Update programmable keys to facilitate selection
  • Interface in several languages: English, Spanish, French, Italian, German and Chinese

Technical specifications

General
BrandThermo Scientific
DescriptionRDO/dissolved oxygen/ temperature module Orion VERSA STAR
ModelOptical/temperature measurement module Orion Versa Star RDO
Pressure range400 to 850 mmHg
Range (OD by polarographic measurement)0 to 90 mg/l; saturation 0 to 600 %
Range (RDO)0 to 50 mg/l; saturation 0 to 500 %
Relative humidity range5 to 85 % non-condensing
Temperature range (metric)-5 to +105°C
Performance
Accuracy (barometer)± 6 mmHg
Accuracy (OD by polarographic measurement)± 0.2 mg/l; saturation ± 2 %
Accuracy (RDO)± 0.1 mg/l up to 8 mg/l, ± 0.2 mg/l from 8 to 20 mg/l, 10% from 20 to 50 mg/l; saturation ± 2%
Accuracy (temperature)±0.1°C
Alarm outputsSet-up point alarm, high/low limit alarm, calibration alarm
Barometric pressure correction400 to 850 mmHg, automatic using integrated barometer or manual input
IP IndexIP-54
IncludesRDO/DO Versa Star module and printed Quick Start Guide
Entry9 pin Mini-DIN (RDO or OD polarographic probe with temperature sensor)
Measurement modesOxygen dissolved in % saturation or mg/l with temperature and barometric pressure
Methods10 per channel with password protection
Percent Saturation Range (POLAROGRAPHIC DO)Saturation from 0 to 600%
Percent Saturation Relative Accuracy (RDO)±2 % saturation ≤ 200 % saturation ±10 % saturation > 200 % saturation
Percent Saturation Resolution (POLAROGRATIC DO)0.1, 1 per cent saturation
Percentage saturation range (RDO)Saturation from 0 to 500 %
Saturation coefficient resolution (RDO)0.1, 1 per cent saturation
Percent Saturation Relative Accuracy (POlarographic DO)Saturation of ± 2 %
Pressure resolution0.1 mmHg
Type of probeOptical dissolved oxygen probe RDO, polarographic dissolved oxygen probe (to be purchased separately)
Resolution (OD by polarographic measure)0.01, 0.1 mg/l; 0.1, 1 per cent saturation
Resolution (RDO)0.01, 0.1 mg/l; 0.1, 1 per cent saturation
Resolution (temperature)0.1°C
Salinity factor0 to 45 ppt
StabilityQuick, medium, slow or Smart Stability parameter selectable; Smart Averaging parameter disabled or automatically selectable
Temperature (metric) in operation5°C to 45°C (ambient temperature)
Temperature selectionAutomatic with temperature sensor ATC
TypeMeasurement Module
Physical characteristics
Dimensions (L x W x H)12°cm x 3°cm x 9,5°cm (4,7°in x 1,2°in x 3,8°in.)
Weight (metric)0.2 kg
Compliance and warranty
Calibration modesSaturated air, saturated water, manual method (Winkler) and zero point
Calibration of the temperature sensorTemperature calibration in 1 point
WarrantyReplacement of the measuring instrument for three years

Origin and customs

Manufacturer ref.VSTAR-RD
Country of originIndonésie
HS customs code9027 89 90 00