Optimized for your water analysis needs, AquaMate 7100 Vis and AquaMate 8100 UV-Vis spectrophotometers provide fast and reliable results
UV-visibles Thermo Scientific™ Orion™ AquaMate spectrophotometers have 260 pre-programmed methods and are designed to meet the needs of water and wastewater analysis laboratories.AquaMate UV-visible and visible spectrophotometers have advanced features and functions for optimal operating flexibility.
More than 260 pre-programmed methods offer...
More than 260 pre-programmed methods offer easy and practical measurements using Orion AQUAfast™, Merck™ or CHEMetrics™ chemistry
Preprogrammed methods can also be used to...
Preprogrammed methods can also be adapted to new chemistry and operators can create their own custom calibration methods and curves
The instruments allow a one-way adjustment...
The instruments allow a one-point adjustment on any pre-programmed method to correct the fluctuations in the chemical properties of the reagents per batch.
Control system with 7-inch touch screen...
7-inch touch screen control system for use with gloves
A wide variety of vial sizes can be used to...
A wide variety of vial sizes can be used, including 10 mm square bottles, 20 mm and 50 mm rectangular bottles, and an adjustable round vial holder that can accommodate bottles and bottles.
The tests of performance verification...
Performance verification tests ensure accuracy of the wavelength and functionality of the instrument
Features
More than 260 pre-programmed methods offer easy and practical measurements using Orion AQUAfast™, Merck™ or CHEMetrics™ chemistry
Preprogrammed methods can also be adapted to new chemistry and operators can create their own custom calibration methods and curves
The instruments allow a one-point adjustment on any pre-programmed method to correct the fluctuations in the chemical properties of the reagents per batch.
7-inch touch screen control system for use with gloves
A wide variety of vial sizes can be used, including 10 mm square bottles, 20 mm and 50 mm rectangular bottles, and an adjustable round vial holder that can accommodate 12 to 25 mm dia. test bottles and tubes.
Performance verification tests ensure accuracy of the wavelength and functionality of the instrument
Each verification report shall indicate the time, date and serial number of the instrument in accordance with BPL and BPF regulations.
The built-in length-in precision test is compatible with the internal lamp or with the external calibrated standards
Integrated test methods for scattering parasitic light, noise and resolution are available for additional instrument validations
Technical specifications
General
Brand
Thermo Scientific
Photometric range
-2 A à +3,5 A
Performance
Linearity of the base line
± 0.002 A
Compartments
Access from the top, front or side. Capable of holding cells up to 100 mm. Available accessory for test tubes up to 25 mm in diameter and 150 mm in height. Removable and washable sample compartment coating with magnetic positioning and fixing system
Connections
Single USB-AExport data to a network or PC via USB, Ethernet or USB Wi-Fi adapter availablePrint via USB, Ethernet or USB Wi-Fi adapter available
For use with (application)
Water and wastewater analysis
Includes
Test tube holder for test bottles and tubes 12 to 25 mm diameter. Ext., 10 mm square cup holder, AquaMate water analysis method software, clip printer, protective cover, external power supply, North American power cable (NEMA 5-15), European power cable (CEE 7/7), British power cable (BS 1362).
Interface
Touch screen for use with gloves
Keyboard
Touch screen for use with gloves
Lamp life
>5 years in general
Length (metric)
35.5 cm
Optical design
Double beam
Photometric accuracy
±0,002 A à 0,5 A, ±0,004 A à 1,0 A, ±0,008 A à 2,0 A
Photometric display
-3A à +5A
Photometric repeatability
±0.001A at 1A measured at 1.0A at 546 nm
Printer included
Clip Printer included
Scanning speed
Slow, medium and fast speeds up to 1,600 nm/min
Parasite light
< 1.0 %T T-198 nm (KCl),
Precision in wavelength
±0.5 nm
Data interval of wavelength
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Repeatability at wavelength
<±0.2 nm
Type of detector
Double silicon photodiodes
Display
7" high-definition color touch screen, fixed, 800 x 1,280 pixels
Spectral bandwidth
2 nm
Type
UV-Vis spectrophotometer
Wavelength Range
190 to 1100 nm
Physical characteristics
Depth (metric)
35.5 cm
Dimensions (L x W x H)
35.5 x 38.5 x 19.5 cm
Height (metric)
19.5 cm
Noise
(RMS at 500 nm, 60 consecutive measurements) ≤0.0002 2 A at 0 A at 260 and 500 nm ≤0.00030 3A at 1 A at 260 and 500 nm ≤0.00040 A at 2 A at 260 and 500 nm
Weight (metric)
7.5 kg
Width (metric)
38.5 cm
Electrical
Power supply
CA / external CC Converter Automatically selected voltage and frequency (Hz), 100/240 V, 50/60 Hz
Plug type
NA, EU, UK Power cord
Compliance and warranty
Certifications/Compliance
CE/TUV
Warranty
1 an
Origin and customs
Manufacturer ref.
AQ8100
Country of origin
China
HS customs code
9027 30 00 00