Kit ELISA sandwich I-TAC/CXCL11 (mouse): quantitative assay of Ms I-TAC in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Ms I-TAC.
Kit ELISA sandwich I-TAC/CXCL11 (mouse): quantitative assay of Ms I-TAC in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Ms I-TAC.
Method principle: This ELISA solid phase sandwich test (immuno-enzymatic dose) measures the amount of target bound between a pair of matched antibodies. A specific target antibody is pre-adsorbed into the wells of the supplied microplate. Samples, standards or controls are added to these wells and bind to immobilized antibodies (capture antibodies). The sandwich is formed by adding the second antibody (detection antibody), then a substrate solution reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this signal is directly proportional to the concentration of the target present in the original sample.
Rigorous validation: Each batch manufactured from this ELISA kit is checked for criteria such as sensitivity, specificity, accuracy and reproducibility from one batch to another (see the package leaflet for more information on validation).
Alpha chemotactic of interferon-inducible T cells (I-TAC), belonging to the CXC chemokine family, is expressed in peripheral blood leukocytes, pancreas and liver, thymus, spleen, lung, small intestine, placenta and prostate. Its molecular weight and 8-11 kDa. The I-TAC is also known as CXCL-11 and IP-9. Cytokine is involved in regulating calcium release and induction of a chemotactic response in activated T cells and is the dominant ligand for the CXC-3 receptor. The gene encoding this protein contains 4 exons and at least three polyadenylation signals that may reflect the specific regulation of expression cells. The IFN-gamma is a powerful inducer of transcription of this gene. It is regulated by the top in patients with AIDS, dementia and in patients with multiple sclerosis.
Sensitivity
Sensitivity of the dosage: 6 pg/ml.
Measurement range
Dose range: 5.487 pg/ml to 4.000 pg/ml.
Duration of dosing
Total dosage duration: 4 hours 45 min.
Samples
Sample type: Plasma, Serum, Surnatant (plasma volume, 50 μl; serum, 50 μl; supernatant, 100 μl).
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 17155709 |
| Specifications |
| Accession number | Q9JHH5 |
| Dose range | 5.487 pg/ml to 4.000 pg/ml |
| Sensitivity of the dosage | 6 pg/ml |
| Calibration range | 6 pg/ml to 4.000 pg/ml |
| Dose | ELISA solid-phase sandwich |
| Conjugate | Biotin |
| Product type | Kit ELISA |
| Protein family | Chemiokine & receptors |
| Type of sample | Plasma, Serum, Surnatant |
| Specificity | This ELISA kit shows no cross-reactivity with the following tested cytokines: mouse CD30, L CD30, T CD40, CRG-2, CTACK, CXCL16, eotaxin, eotaxin-2, Ligand Fas, fractalkine, GCSF, GM-CFS, IFN-gamma, IGFBP-3, IGFBP-5, IGFBP-6, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-3 Rb, IL-4, IL-5, IL-5, IL- |
| Sufficient for | 5 x 96 dosages |
| Target species | Mouse |
| For use with (application) | ELISA, protein dosage, protein biology, cancerology, immunology, neuroscience, neurobiology, protein detection, protein analyses |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | 56066 |
| Gene symbol(s) | Cxcl11 |
| Coefficient of inter-dose variation | <12% |
| Coefficient of intra-dose variation | <10% |
| Contents of kits | SAV-HRP, 96-well pre-coated plates, Wash pad, Biotinylated detection antibody, Chromogen, Adhesive plate covers, Stop solution, Dose diluent concentrate, Calibration standard |
| Marker or dye | HRP |
| Quantity | 5 x 96 tests |
| Regulatory status | RUO |
| Research disciplines | Inflammation |
| Synonym | Cxc11, H174, I-tac, Ip9, Itac, Scyb11, Scyb9b, b-R1, betaR1 |
| Target | Mouse |
| Test time | 1 hour 20 minutes. |
| Physical characteristics |
| Volume of sample | Plasma, 50 μl; serum, 50 μl; supernatant, 100 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 4:45 a.m. |
Origin and customs
| Manufacturer ref. | EMCXCL11X5 |
|---|
| Country of origin | United States |
|---|