The ELISA mouse RANTES test quantifys mouse RANTES in serum, plasma, buffer solution or mouse cell culture medium. The dosage will only recognize the presence of natural and recombinant M RANTES....
The ELISA mouse RANTES test quantifys mouse RANTES in serum, plasma, buffer solution or mouse cell culture medium. The dosage will only recognise the presence of natural and recombinant MANTES. Principle of the L-ELISA solid phase sandwich RANTES method for mice (immuno-enzymatic test) is designed to measure the amount of the target bound between a pair of matched antibodies. A target-specific antibody was pre-vested in the wells of the supplied microplate. Samples, standards or controls are then added to these wells and bound to immobilized antibody (capture). The sandwich is formed by adding the second antibody (detector), a substrate solution that reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this coloured product is directly proportional to the concentration of TP (p) present in the original sample. Rigorous validation Each batch manufactured from this ELISA kit is tested for quality for criteria such as sensitivity, specificity, accuracy and batch-to-batch consistency. See the product manual for more information on validation.
Acknowledges the natural and recombinant IP-10. Order information
Shipping conditions: Wet ice
Measurement range
Dose range: 11.7-750 pg/ml.
Duration of dosing
Total duration of dosing: 4 hours.
Reproducibility
Coefficient of variation in intra-dose 2.2%, inter-dose 5.3%.
Samples
Type of sample: Serum, Surnatant, Surnatant (plasma volume, 50 μl; Serum, 50 μl; Supernatant, 50 μl).
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 10672644 |
| Specifications |
| Accession number | P30882 |
| Dose range | 11.7-750 pg/ml |
| Sensitivity of the dosage | <5 pg/ml |
| Conjugate | Biotin |
| Product type | Kit ELISA |
| Type of sample | Serum, Surnatant, Surnatant |
| Target species | Mouse |
| For use with (application) | Colorimetric |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | 20304 |
| Gene symbol(s) | MuRantes,RANTES,SISd,Scya5,TCP228 |
| Coefficient of inter-dose variation | 5.3% |
| Coefficient of intra-dose variation | 2.2% |
| Contents of kits | 96-well pre-coated plate, Streptavidine HRP, HRP diluent, Wash pad, Chromogen, Stop solution, Adhesive plate covers |
| Marker or dye | HRP |
| Accuracy | <5 pg/ml |
| Quantity | 96 tests |
| Regulatory status | RUO |
| Target | Mouse |
| Test time | 1 h 20 min |
| Physical characteristics |
| Volume of sample | Plasma, 50 μl; Serum, 50 μl; Supernatant, 50 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 4 h |
Origin and customs
| Manufacturer ref. | KMC1031 |
|---|
| Country of origin | Autriche |
|---|
| HS customs code | 3002 15 00 00 |
|---|
A question or a specific configuration?