Water purification system Sartorius Arium® pro H2OPRO-UF-B – Arium pro UF

Ref.: BL-EQ-928077Manufacturer ref.: H2OPRO-UF-B
Price on request
Custom pricing depending on configuration and quantity.

Water purification system Sartorius Arium® pro H2OPRO-UF-B (ref. H2OPRO-UF-B), Arium pro UF: pure and ultra-pure water production in the laboratory.

Reference
H2OPRO-UF-B
Brand
Sartorius

Water purification system Sartorius Arium® pro H2OPRO-UF-B (ref. H2OPRO-UF-B), Arium pro UF: pure and ultra-pure water production in the laboratory.

The ASTM Type 1* Arium Water Purification Systems® The Commission shall take the necessary measures to ensure that the water used is used for the purpose of ensuring that the water used is used for the purpose of ensuring that the water used is used for the purpose of critical applications and routine analysis. The system provides water of high quality and constant quality that is perfect for your applications. The Arium series® pro includes five different versions for reliable and optimal analysis results, depending on the specific applications needs with either or without UV lamp or ultrafilter, and with or without COTmètre: Arium® pro DI , Arium® pro UV , Arium® pro UF , Arium® pro VF. You can opt for an economical version that provides all the essential performance features you need in a laboratory water purification system: Arium® pro. Arium system® pro UF wall version for ultra-pure water production for cell culture applications, with display and draw-out unit installed in the bottom of the front and with integrated wall support for the system

Standard applications:
  • HPLC
  • GC-MS, AAS, ICP-MS
  • Ion chromatography
  • Analysis of COT
  • PCR
  • Electrophoresis
  • Endotoxin analyses
  • Inmunocytochemistry
  • Pure water for the preparation of growing media
  • Pure water for the production of monoclonal antibodies
  • Photometry
Lowest COT content

The 185-254 nm UV lamp, which can be optionally integrated, not only prevents microbiological growth, but also reduces organic compounds (OTCs) in purified water. The low level of COT < 2 ppb in ultrapurous water, therefore ensures the reproducibility and reliability of your laboratory results. However, you can have COT readings, measured continuously and displayed in real time by our optional, developed and integrable COT analyzer for this water system. To ensure the effective elimination of endotoxins, micro-organisms and particles as well as Dnase and Rnase, you can opt for an Arium system® pro with integrated ultrafilter, with the most advanced technology with hollow fibers. This ultrafilter allows the Arium® The project will provide a wide range of services to the public, including:

Main advantages of the Arium® pro :
  • Modular units preassembled according to specific applications
  • The lowest COT level with the real-time measurement option
  • Effective and remarkable elimination of endotoxins, Rnase and Dnase
  • High flexibility
  • A simple use of the

In addition to the advantages already mentioned, the Arium® pro offers an impressive range of additional features, such as choice of distribution options, data backup and printing functions as well as a color code messaging and associated alarm information, etc. The Arium® pro is the best choice for your daily applications in Molecular Biology (RNase & DNase & Endotoxins Free)

Hydraulic diagram of the Arium model® pro UF and conventional applications

In addition to the kit of two purification cartridges with a unique design, the Arium system® UF includes an ultrafilter to effectively eliminate endotoxins, pyrogens, DNA, RNA, etc. The microporous membrane of 5000 Dalton retains the macromolecules and the purified water obtained is thus perfectly suited for use in cell culture applications. The classic applications are:

  • Cell culture
  • DNA sequence analysis
  • FIV (In Vitro Fertility)
  • General applications in biochemistry

GC-MS, AAS, ICP-MS

GC-MS, AAS, ICP-MS

Ion chromatography

Ion chromatography

Analysis of COT

Analysis of COT

Electrophoresis

Electrophoresis

Endotoxin analyses

Endotoxin analyses

Technical specifications

General
BrandSartorius
Consumption of ultra-pure water<100 L/day
RangeArium® pro
Installation optionWall-fixed
Type of water systemType 1 Ultrapure Lab Water System
Type of water product availableType 1 (18.2 MΩ × cm / 0 055 μS/cm)
Performance
Minimum input pressure6.9 bar
Water supply sourcePre-treated water supply with DI or RO or EDI
Specifications
Bacteria (CFU/1000 ml)< 1
Water distribution rate (Type 1)1.7 L/min
Level COT (depending on the water supplied)< 5 ppb (ASTM Type I)
Particulate matter (0.2 µm)< 1/mL
Resistivity of produced water (at 25 °C)18.2 MΩ × cm
Physico-chemical characteristics
Total organic carbon (COT)< 5 ppb
Conductivity (μS/cm)0 055 µS/cm
Endotoxin< 0.001 EU/mL
Silica level< 1000 ppb
Turbidity< 1 NTU
Low values in Endotoxins , Rnase & DnaseYes
Electrical
Voltage100 – 240 V
Terms of use
Maximum input pressureDepressurised
Applications
ApplicationGeneral laboratory applications (stamps, media, rinse, ELISA, electrophoresis, photometry) Life sciences applications (DNA sequencing, endotoxin analysis, PCR, cell culture)

Origin and customs

Manufacturer ref.H2OPRO-UF-B
Country of originGermany
HS customs code8421 21 00 00
A question or a specific configuration?
Contact us for a quote.