Langential ultrafiltration Cassette Sartorius Vivaflow® (ref. VF-S050H0100-SV), cut-off threshold 100 kDa, regenerated cellulose: concentration of large volumes by tangential filtration.
Vivaflow 50 is a single-use tangential filter cassette ready for filtration and concentration of 100 ml to 1 L samples per module. The membrane surface of each system is 50 cm2. Each package includes two cassettes and comes with all the accessories necessary for their proper operation with a peristaltic laboratory pump and pump head, size 16. To speed up concentration and increase flow, it is possible to connect up to six cassettes. Ideal for applications such as concentration of cell culture supernatants, concentration of viruses and water as in the peasing panture facilities, this economical product is distinguished by ease of use, reliability and flexibility unmatched by other filtration systems available on the market. The narrow zig-zag channel, the recirculation circuit of this module, allows high tangential filtration speeds while keeping low pump pressures. A single 50 cm2 module reduces the sample from 500 ml to 15 ml in less than 50 minutes. Almost total recovery of the concentrate is achieved with a single rinse. Six modules can be connected in series or in parallel for a simplified scale-up, which allows to process a volume of several litres. Vivaflow 50 is for single use only. All accessories, except the peristaltic pump with a size 16 head, are included in the kit. The transparent modules allow simple control of the remaining volume and the state of the membrane. A 500 ml sample and diafiltration tank, waterproof, can be added to the system for quick and easy buffer change. Equipment The standard Vivaflow 50 pack includes two cassettes, tubes, a flow reducer, a series of interconnectors and a high pressure pump tube. You only need a peristaltic pump with a pump head suitable for tubes with an external diameter of 6.4 mm (size 16). Using more than two Vivaflow 50 devices in parallel and in series To speed up concentration, up to six Vivaflow 50 cassettes can be easily connected with 2 T-connectors to connect 2 Vivaflow modules to the input and output and with a series of interconnectors to connect the systems between them. A pressure indicator shall be installed at the inlet to allow optimal control. High flow and efficiency Transparent case for process control Ready-to-use individual Cassettes Easy installation of multiple cassettes One-time, economical product in performance A single 50 cm2 module typically reduces the sample from 500 ml to less than 15 ml in less than 50 minutes. Less than 10 ml of minimum recirculation volume in the system at higher concentrations. Less than 500 µl are lost in dead volume. Almost all is recoverable with a single 10 ml rinse. Performance characteristics
Large volumes
Fast concentration from 100 mL to several litres.
Tangential filtration
Limit membrane clumping.
Simple mounting
Works with a standard peristaltic pump.
Technical specifications
| General |
| Brand | Sartorius |
| Range | Vivaflow® |
| Type of sample | Exosome Nanoparticles Nucleic acid Protein Peptide Viral vector Virus Water |
| Type of filter | TFF |
| Physico-chemical characteristics |
| Cut-off threshold (MWCO) | 100 kDa |
| Materials |
| Constitutive material of the membrane | Hydrosart® Regenerated Cellulose (RC) |
| Tube material | Vinyl PolyChlorure (PVC) |
| Body materials | Polycarbonate (PC) |
| Physical characteristics |
| Membrane surface | 50 cm² |
| Terms of use |
| Recommended flow rate | 200 - 400 mL/min |
| Maximum operating pressure | 3 bar |
| Recommended feed volume | 500 - 1 000 mL |
| Minimum retention volume | 10 mL |
| Applications |
| Application | Ultrafiltration Diafiltration |
| Scope of application | Buffer exchange Concentration Desalting Enrichment Formulation Fractionation Polishing |
| Intended use | General laboratory use |
| Compliance |
| Certification | ISO 9001 standard |
Origin and customs
| Manufacturer ref. | VF-S050H0100-SV |
|---|
| HS customs code | 8421 29 80 00 |
|---|
A question or a specific configuration?
Contact us for a quote.