Sartorius Vivacon® centrifugal concentrate (ref. VN02H42ETO), 100 kDa cut-off threshold, Hydrosart®: ultrafiltration protein concentration and desalination.
Reference
VN02H42ETO
Brand
Sartorius
Sartorius Vivacon® centrifugal concentrate (ref. VN02H42ETO), 100 kDa cut-off threshold, Hydrosart®: ultrafiltration protein concentration and desalination.
The Vivacon 2 centrifugal centrifugal concentrate is an ultrafiltration unit dedicated to concentration/recovery and buffer change for applications of genomic DNA and peptides in biological samples up to 2 ml. It is also the product of choice for peptide fractionation applications in this volume range. For better performance on heavily diluted samples, such as forensic specimens, Vivacon 2 has a regenerated cellulose membrane, patented Hydrosart® which guarantees very low parasitic adsorption and excellent flow. The selected cut-off thresholds (MWCO) are available in sterile and DNA-free versions (PCR grade units). They were treated with a double ethylene oxide (ETO) sterilization cycle to ensure that they are sterile at a safety level of 106 and without detectable contamination of human genomic DNA. Tests were conducted with a qPCR assay of more than 55 cycles with a verified detection limit of 2 pg. High yields and reproducibility are associated with the practical side offered by the MWCO printed on the side of the tube. Vivacon 2, unlike the Vivaspin classics, is designed with a horizontal membrane that is recommended for the fractionation of DNA elimination of primers) as well as the fractionation of peptides (FASP1 Preparation of filter-assisted sample). The possibility of reverse centrifugation after treatment of the sample ensures the complete concentrated recovery of the particularly interesting concentrate during the treatment of samples of low concentrations. 1Wisniewski JR, Zugman A, Nagaraj N, Mann M. Universal Sample Preparation Method for Proteomics Analysis (2009). Methods nat. 5:359-62. Concentration up to 2 ml of samples of genomic DNA or peptide Low adsorption material Possibility of reverse centrifugation Graduation and cut-off threshold (MWCO) printed on the device Complete and highly reproducible recovery of the concentrate Selected cut-off thresholds available in sterile and DNA-free version*, e.g. for forensic applications * 55-cycle qPCR test with a verified detection limit of < 2 pg. Performance characteristics for DNA Initial volume of 2 ml, sample concentration of 50 ng/ml. ' Performance characteristics for proteins Initial volume of 2 ml, sample type and protein concentration rate as specified in the table.
Rapid concentration
Ultrafiltration in centrifuge with oscillating or fixed rotor.
Choice of cut-off threshold
PES, CTA or regenerated cellulose membranes (Hydrosart®).