Invitrogen™ Lymphotactin/XCL1 Mouse ELISA Kit

Ref.: BL-RE-093127Manufacturer ref.: EMXCL1 96 tests
€704.00 excl. VAT

Kit ELISA Lymphotactin/XCL1 sandwich (mouse): quantitative assay of Ms Lymphotactin in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Ms Lymphotactin.

Accession number
P47993
Dose range
46.9-3000 pg/ml
Sensitivity of the dosage
40 pg/ml
Calibration range
40 pg/ml to 3000 pg/ml
Dose
ELISA solid-phase sandwich
Brand
Invitrogen

Kit ELISA Lymphotactin/XCL1 sandwich (mouse): quantitative assay of Ms Lymphotactin in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Ms Lymphotactin.

Kit ELISA Lymphotactin/XCL1 sandwich (mouse): quantitative assay of Ms Lymphotactin in serum, plasma or cell culture medium. The test recognizes only the natural and recombinant forms of Ms Lymphotactin.

Method principle: This ELISA solid phase sandwich test (immuno-enzymatic dose) measures the amount of target bound between a pair of matched antibodies. A specific target antibody is pre-adsorbed into the wells of the supplied microplate. Samples, standards or controls are added to these wells and bind to immobilized antibodies (capture antibodies). The sandwich is formed by adding the second antibody (detection antibody), then a substrate solution reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this signal is directly proportional to the concentration of the target present in the original sample.

Rigorous validation: Each batch manufactured from this ELISA kit is checked for criteria such as sensitivity, specificity, accuracy and reproducibility from one batch to another (see the package leaflet for more information on validation).

Lymphotactin, otherwise known as XCL1, is a member of the C-chemiokine family that acts in a unique way as a chemotactic for lymphocytes, but not monocytes or neutrophils, suggesting an important regulatory role in the trafficking and inflammation of lymphocytes. Lymphotactin, whose signal is transmitted by the chemokine receptor XC 1 (XCR1), is detected at the highest level of the spleen and at low levels in the lungs, small intestines and colon, and is expressed in abundance and selectively by activated T cells, especially CD8+ T cells, and is also produced by NK cells.

Sensitivity

Sensitivity of the dosage: 40 pg/ml.

Measurement range

Dose range: 46.9-3000 pg/ml.

Duration of dosing

Total duration of dosing: 4 h 45 min.

Reproducibility

Intradose variation coefficient < 10%, interdose < 12%.

Target

Target: Mouse.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)15495353
Specifications
Accession numberP47993
Dose range46.9-3000 pg/ml
Sensitivity of the dosage40 pg/ml
Calibration range40 pg/ml to 3000 pg/ml
DoseELISA solid-phase sandwich
ConjugateBiotin
Product typeKit ELISA
Protein familyChemiokine & receptors
Type of sampleSerum, Surnatant, Surnatant
SpecificityThis ELISA kit shows no cross-reactivity with the following tested cytokines: CD30, L CD30, T CD40, CRG-2, CTACK, CXCL16, eotaxin, eotaxin-2, ligand Fas, Fractalkine, GCSF, GM-CFS, IFN-gamma, IGFBP-3, IGFBP-5, IGFBP-6, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-3 Rb, IL-4, IL-5, IL-9, IL-10,
Sufficient for96 dosages
Target speciesMouse
For use with (application)ELISA, protein dosage, protein biology, cancerology, immunology, neuroscience, neurobiology, protein detection, protein analyses
For use with (equipment)Colorimetric microplate reader
Genetic identification (Enter)16963
Gene symbol(s)AI661682,ATAC,LTN,Lptn,SCM-1,SCM-1a,Scyc1
Coefficient of inter-dose variation< 12 %
Coefficient of intra-dose variation< 10 %
Contents of kits96-well pre-coated plate, Standard, Dose diluent concentrate, Biotinylated detection antibody, Wash pad, Chromogen, Stop solution, Adhesive plate covers, Adhesive plate covers
Marker or dyeHRP
Quantity96 tests
Regulatory statusRUO
Research disciplinesInflammation
SynonymAI661682, ATAC, LTN, Lptn, SCM-1, SCM-1a, Scyc1
TargetMouse
Test time1 h 20 min
Physical characteristics
Volume of samplePlasma, 50 μl; Serum, 50 μl; Supernatant, 100 μl
Storage and shipping
Storage conditions2°C to 8°C
Total duration of dosing4 h 45 min

Origin and customs

Manufacturer ref.EMXCL1
Country of originUnited States
HS customs code3002 15 00 00