Human ST8SIA2 quantitates human ST8SIA2 in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human ST8SIA2.
Human ST8SIA2 quantitates human ST8SIA2 in serum, plasma, supernatant. The assay will exclusively recognize both natural and recombinant human ST8SIA2.
The protein encoded by this gene is a II membrane protein that appears to catalyze the transfer of sialic acid from sialic acid-CMP to N-bound glycoproteins and oligosaccharides. The coded protein can be found in the Golgi apparatus and may be involved in the production of polysialic acid, a modulator of the adhesive properties of the neural cell adhesion molecule (NCAM1). This protein belongs to the family 29 of glycosyltransferases.
Sensitivity
Sensitivity of the dosage: 0.05 ng/ml.
Measurement range
Dosing range: 0.05 to 10 ng/ml.
Duration of dosing
Total duration of dosing: 4 h 45 min.
Reproducibility
Coefficient of intradose variation < 10%, interdose < 12%.
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 17854150 |
| Specifications |
| Accession number | Al323367; alpha-2.8-sialyltransferase 8 B; alpha-2.8-sialyltransferase 8 B 1; HsT19690; MGC116854; MGC116857; Synthase of polysialic acid; sialyltransferase 8 (alpha-2 8-sialyltransferase) B; sialyltransferase 8 (alpha-2, 8-sialyltransferase) B; sialyltransferase 8 (alpha-2, 8-sialyltransferase) B; sialyltransferase 8 (alpha-2, 8-sialyltransferase) |
| Dose range | 0.05 to 10 ng/ml |
| Sensitivity of the dosage | 0.05 ng/ml |
| Conjugate | Biotin |
| Product type | ELISA |
| Type of sample | Plasma, Serum, Surnatant |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | Q92186 |
| Gene symbol(s) | ST8SIA2 |
| Coefficient of inter-dose variation | < 12% |
| Coefficient of intra-dose variation | < 10% |
| Contents of kits | 96-well pre-coated plate, standard, dosing diluent concentrate, biotinylated detection antibody, SAV-HRP, washing pad, chromogen, stop solution, adhesive plate lids |
| Marker or dye | HRP |
| Quantity | 10 x 96 tests |
| Regulatory status | Use exclusively for research |
| Target | ST8SIA2 |
| Test time | 1 h 20 min |
| Physical characteristics |
| Volume of sample | Serumt, 50 μl; supernatant, 50 μl; plasma, 50 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 4 h 45 min |
Origin and customs
| Manufacturer ref. | EH440RBX10 |
|---|
| Country of origin | United States |
|---|
| HS customs code | 3002 12 00 00 |
|---|
A question or a specific configuration?