Protein tyrosine nitration results in a post-translational modification that is increasingly receiving attention as an important component of nitric oxidesignaling. While multiple nonenzymatic mechanisms are known to be capable of producing nitrated…
Protein tyrosine nitration results in a post-translational modification that is increasingly receiving attention as an important component of nitric oxidesignaling. While multiple nonenzymatic mechanisms are known to be capable of producing nitrated tyrosine residues, most tyrosine nitration events involve catalysis by metalloproteins such as myeloperoxidase, eosinophilperoxidase, myoglobin, the cytochrome P-450s, superoxide dismutase and prostacyclin synthase. Various studies have shown that protein tyrosinenitration is limited to specific proteins and that the process is selective. For example, exposure of human surfactant protein A (SP-A) to oxygen-nitrogen intermediates generated by activated alveolar macrophages resulted in specific nitration of SP-A at tyrosines 164 and 166, while addition of 1.2 mMCO 2 resulted in additional nitration at tyrosine 161. The presence of nitrotyrosine-containing proteins has shown high correlation to disease states such as atherosclerosis, Alzheimer’s disease, Parkinson’s disease and amyotrophic lateral sclerosis.
Sensitivity
Sensitivity of dosage: 0.94 ng/mL.
Measurement range
Dose range: 1.56 to 100 ng/mL.
Duration of dosing
Total duration of dosing: 3 h 30 min.
Samples
Sample type: Serum (volume 50 µL).
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 18007424 |
| Specifications |
| Dose range | 1.56 to 100 ng/mL |
| Sensitivity of the dosage | 0.94 ng/mL |
| Conjugate | HRP |
| Product type | ELISA |
| Type of sample | Serum |
| For use with (equipment) | Colorimetric Microplate Reader |
| Coefficient of inter-dose variation | <10% |
| Coefficient of intra-dose variation | <10% |
| Contents of kits | Pre-coated 96 well flat, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Dilute, Biotinylated Detection Antibody Dilute, HRP Conjugate Dilute, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marker or dye | HRP |
| Quantity | 96 Tests |
| Regulatory status | RUO |
| Target | All |
| Test time | 1 hr 20 min |
| Physical characteristics |
| Volume of sample | 50 µL |
| Storage and shipping |
| Storage conditions | Refer to product documentation for component specific storage temperature. |
| Total duration of dosing | 3 hr 30 min |
Origin and customs
| Manufacturer ref. | EEL008 |
|---|
| Country of origin | China |
|---|
| HS customs code | 3822 11 00 00 |
|---|
A question or a specific configuration?