The human monocyte specific ELISA chemokine 3 test (CCL7) (human MCP-3) quantifies human MCP3 in serum, plasma, buffered solution or human cell culture medium. The test will recognize exclusively the MCP-3 Hu...
The human monocyte specific ELISA chemokine 3 test (CCL7) (human MCP-3) quantifies human MCP3 in serum, plasma, buffered solution or human cell culture medium. The test will recognize only natural and recombinant MCP-3 Hu. Method Principle The human MCP-3 solid phase ELISA sandwich test (immuno-enzymatic test) is designed to measure the amount of the target bound between a pair of matched antibodies. A target-specific antibody was pre-vested in the wells of the supplied microplate. Samples, standards or controls are then added to these wells and bound to immobilized antibody (capture). The sandwich is formed by adding the second antibody (detector), a substrate solution that reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this coloured product is directly proportional to the concentration of TP (p) present in the original sample. Rigorous validation Each batch manufactured from this ELISA kit is tested for quality for criteria such as sensitivity, specificity, accuracy and batch-to-batch consistency. See the product manual for more information on validation.
It is a secreted chemokin that attracts macrophages during inflammation and metastases. It is part of the C-C subfamily of chemokines that are characterized by two adjacent cysteine residues. The protein is an in vivo substrate of matrix metalloproteinase 2, an enzyme that degrades the components of the extracellular matrix.
Sensitivity
Sensitivity of the dosage: 0.1 pg/ml.
Measurement range
Dose range: 0.3-20.0 pg/ml.
Duration of dosing
Total duration of dosing: 3 h 15 min.
Reproducibility
Coefficient of variation between doses 5.5%, interdose 4.2%.
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 15541677 |
| Specifications |
| Accession number | P80098 |
| Dose range | 0.3-20.0 pg/ml |
| Sensitivity of the dosage | 0.1 pg/ml |
| Conjugate | Biotin |
| Product type | Kit ELISA |
| Type of sample | Serum, Surnatant, Supernatant |
| Target species | Human |
| For use with (application) | ELISA |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | 6354 |
| Gene symbol(s) | FIC,MARC,MCP-3,MCP3,NC28,SCYA6,SCYA7 |
| Coefficient of inter-dose variation | 4.2% |
| Coefficient of intra-dose variation | 5.5% |
| Contents of kits | 96-well pre-coated plate, Stalion, Sample thinner, Dose buffer concentrate, Biotinylated detection antibody, Wash pad, Chromogen, Stop solution, Adhesive Plate Covers, Adhesive Plate Covers |
| Marker or dye | HRP |
| Quantity | 96 Tests |
| Regulatory status | RUO |
| Synonym | FIC, MARC, chemotactic protein of monocytes 3 |
| Target | Human |
| Test time | 1 h 20 min |
| Physical characteristics |
| Volume of sample | Plasma, 50 μl; Serum, 50 μl; Supernatant, 50 μl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 3 h 15 min |
Origin and customs
| Manufacturer ref. | BMS2125 |
|---|
| Country of origin | Autriche |
|---|
| HS customs code | 3002 15 00 00 |
|---|
A question or a specific configuration?