The uncoated ELISA d-interleukin-6 alpha (IL-6) kit contains antibody pairs, pre-matched plates and reagents for quantitative immunoenzymatic testing (ELISA) to detect and quantify levels of erythropoie...
The uncoated ELISA d-interleukin-6 alpha (IL-6) kit contains pairs of antibodies, pre-matched plates and reagents for quantitative immunoenzymatic (ELISA) tests to detect and quantify rat l-L-6 protein levels. The washing pad and stop solution are necessary to complete the ELISA reaction and are sold separately. Method Principle ELISAs are designed to measure the amount of the target bound between a pair of matched antibodies. A target-specific antibody is coated at the bottom of the wells of a microplate; it is a night process. Samples, standards or controls are then added to these wells and bound to immobilized antibody (capture). A sandwich is formed by adding the second antibody (detector), a substrate solution that reacts with the enzyme-antibodies-target complex to produce a measurable signal. The intensity of this coloured product is directly proportional to the concentration of TP (p) present in the original sample.
The interleukin 6 (IL-6) is a 26 kD multifunctional protein initially discovered in the medium of fibroblastoid cells stimulated by the RNA. The IL-6 appears to be directly involved in responses after infection and cell damage, and may be as important as the IL-1 and TNF-a in the regulation of acute phase response. The IL-6 is apparently produced by fibroblasts, activated T cells, activated monocytes or macrophages and endothelial cells. The IL-6 acts on a variety of cells, including myeloid stem cells, T cells, B cells and hepatocytes. In addition, the IL-6 appears to interact with the IL2- in T-cell proliferation. The proliferative effect of the IL-3 on multipotential hematopoietic progenitors is potentiated by the IL-6. The IL-6 plays an essential role in the differentiation of B cells into plasma cells and is a powerful growth factor for plasmacytoma and myeloma. The IL-6 is a very useful crop supplement for the generation of a large number of antibody-producing hybridomas. Mainly produced at acute and chronic inflammation sites, the IL-6 is secreted in serum and induces a transcriptional inflammatory response via the interleukin 6 alpha receptor. The functioning of the IL-6 is involved in a wide variety of pathological states associated with inflammation, including diabetes mellitus and juvenile systemic rheumatoid arthritis.
Sensitivity
Sensitivity of the dosage: < 46.9 pg /ml.
Measurement range
Dose range: 46.9 to 3.000 pg/ml.
Duration of dosing
Total duration of dosing: 24 h 30 min.
Samples
Sample volume: Surnatant, 50 µl; Serum, 50 µl; Plasma, 50 µl.
Technical specifications
| General |
| Brand | Invitrogen |
| Supplier ref. (Fisher Scientific) | 17134153 |
| Specifications |
| Accession number | B cell differentiation factor; B hybridoma growth factor; B cell stimulation factor 2; BSF2; BSF-2; CDF; ChIL-6; differentiation factor CTL; cytokine; HGF; H-IL-6; HSF ; hybridoma growth factor ; Ifnb2; IFN-beta-2; IL6; Il-6; Ilg6 |
| Dose range | 46.9 to 3.000 pg/ml |
| Sensitivity of the dosage | < 46.9 pg /ml |
| Conjugate | Biotin |
| Product type | ELISA |
| For use with (equipment) | Colorimetric microplate reader |
| Genetic identification (Enter) | P20607 |
| Gene symbol(s) | Il6 |
| Contents of kits | Capture Antibody: Pretitled Purified Antibody Detection antibody: Pretitrated antibody, combined with biotin Standard: Recombinant protein to generate the standard curve and calibrate samples 10 x coating pad: Stamp for veneering l ’enzyme tampon d |
| Marker or dye | HRP |
| Quantity | 10 x 96 tests |
| Regulatory status | Use exclusively for research |
| Target | IL-6 |
| Test time | 1 h 45 min |
| Physical characteristics |
| Volume of sample | Supernatant, 50 µl; Serum, 50 µl; Plasma, 50 µl |
| Storage and shipping |
| Storage conditions | 2°C to 8°C |
| Total duration of dosing | 24 h 30 min |
Origin and customs
| Manufacturer ref. | 88-50625-88 |
|---|
| Country of origin | Autriche |
|---|
| HS customs code | 3002 12 00 00 |
|---|
A question or a specific configuration?