Invitrogen™ Human Renin ProcartaPlex™ Simplex Kit

Ref.: BL-RE-097510Manufacturer ref.: EPX010-12447-901 96 Tests
€349.00 excl. VAT

The Human Renin ProcartaPlex Simplex Kit measures renin protein and is designed to be combinable with other Simplex kits so that users can create their own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation.…

Product type
Simplex Kit
Quantity
96 Tests
Species
Human
Combinability
Combined
Type of microbead
Magnetic
Brand
Invitrogen

The Human Renin ProcartaPlex Simplex Kit measures renin protein and is designed to be combinable with other Simplex kits so that users can create their own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation.…

The Human Renin ProcartaPlex Simplex Kit measures renin protein and is designed to be combinable with other Simplex kits so that users can create their own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

About ProcartaPlex assays for the Luminex platform

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 μL of plasma or serum, or 50 μL of cell culture supernatant, and just four hours to obtain analyzed results.

• More results per sample—measure multiple protein targets simultaneously in a single 25–50 μL sample

• Well-established Luminex technology—highly referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 65 protein targets in a single 25–50 μL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create spectrally unique signatures that can be identified by the Luminex xMAP detection systems (e.g., Luminex 200, FLEXMAP 3D, and MAGPIX). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine).

Reproducibility

Coefficient of variation intra-dose As determined for Lot 1: 6.2 %, inter-dose As determined for Lot 1: 7.4%.

Species

Species: Human.

Samples

Sample volume: Urine, Serum, Plasma: 25 μLCCS: 50 μL.

Compatibility

Designed for use with: Luminex™ Instruments.

ProcartaPlex™ range

It is part of the ProcartaPlex™ range.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)17856012
Specifications
Product typeSimplex Kit
Quantity96 Tests
SpeciesHuman
CombinabilityCombined
Type of microbeadMagnetic
Microbead areaRenin [46]
Sensitivity of the dosageAs determined for Lot 1: 0.5 pg/mL
Dose rangeAs determined for Lot 1: 4–14.2 pg/mL
FormatSimplex Kit (combinable)
For use with (equipment)Luminex™ Instruments
ExpressionREN
Genetic identification (Enter)5972
High-throughput compatibilityYes (384-well Mix and Match panel)
Coefficient of inter-dose variationAs determined for Lot 1: 7.4%
Coefficient of intra-dose variationAs determined for Lot 1: 6.2 %
Product rangeProcartaPlex™
Type of sampleUrine, Serum, Plasma, Cell Culture Supernatants (CCS)
ID UniProtP00797
dimResearchAreaToxicology
Physical characteristics
Volume of sampleUrine, Serum, Plasma: 25 μL
CCS: 50 μL
Storage and shipping
Content and storage1 vial Capture Beads (50x)
1 vial biotinylated Detection Antibody (50x)
2 vials Standard Mix (lyophilized)

Store at 2-8°C.
Shipping conditionsWet Ice

Origin and customs

Manufacturer ref.EPX010-12447-901
Country of originAutriche
HS customs code3822 11 00 00
A question or a specific configuration?
Contact us for a quote.