Invitrogen™ GM-CSF Human ProcartaPlex™ Simplex Kit, high sensitivity

Ref.: BL-RE-097900Manufacturer ref.: EPXS010-10283-901 96 dosages
€398.00 excl. VAT

ProcartaPlex high sensitivity immunological assays allow multiplexed analysis of human and mouse analyses in very low concentrations in various matrices, including serum, plasma, body fluids, etc.

Product type
Simplex kit
Quantity
96 dosages
Species
Human
Combinability
Combine (high sensitivity only)
Type of microbead
GM-CSF [44 ]
Brand
Invitrogen

ProcartaPlex high sensitivity immunological assays allow multiplexed analysis of human and mouse analyses in very low concentrations in various matrices, including serum, plasma, body fluids, etc.

High sensitivity ProcartaPlex immunological assays allow multiplexed analysis of human and mouse analyses at very low concentrations in various matrices, including serum, plasma, body fluids, and cell culture supernatants (SCC). These high sensitivity multiplex assays are ideal when the volume of samples is limited and protein expression is in the lower range of pg/ml.

ProcartaPlex immunoassays are based on the principles of d-ELISA sandwich, using two highly specific antibodies binding to different epitopes of a protein to simultaneously quantify up to 80 protein targets using Luminex 200 or FLEXMAP 3D and up to 50 protein targets using the MAGPIX instrument. ProcartaPlex assays require only 25 µl plasma or serum, or 50 µl cell culture supernatant, and only four hours to obtain analyzed results.

• Plus of results per sample — Measurement of up to 80 protein targets in a single sample of 25 - 50 µl

• Well established Luminex technology — The best referenced multi-dimensional platform for protein detection and quantification

The Luminex MagPlex Superparamagnetic Microspheres of the ProcartaPlex assay are coloured internally with precise proportions of red and infrared Fluorophores to create 100 unique spectral signatures that can be identified by Luminex xMAP detection systems (Luminex 200, 3D flexmap and MAGPIX systems). Like the ELISA sandwich assay, ProcartaPlex uses paired antibody pairs to identify the protein of interest. In a multiplex ProcartaPlex assay, each single spectral microbead is marked with single target protein-specific antibodies and the bound proteins are identified with biotinyl antibodies and streptavidine–R-phycoerythrin (RPE). The combination of specific antibodies from a protein to a separate microbead allows for the analysis of several targets in a single well.

The most significant difference between ProcartaPlex and ELISA is that the ProcartaPlex capture antibody is combined with a magnetic microbead and is not absorbed into the microplate well, so that ProcartaPlex dosing reagents float freely in the solution. For detection purposes, Luminex 200, for example, contains two lasers: one to distinguish the spectral signature from each microbead and one to quantify the amount of fluorescence of RPE. The latter is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using a smaller sample with the same duration as a conventional ELISA sandwich.

Simplex ProcartaPlex kits create your own unique panel. More than 90% of human ProcartaPlex targets can be combined, offering you greater flexibility when creating your own multiplexed panel.

Sensitivity

Sensitivity of the dosage: Less than 15%.

Measurement range

Dose range: As determined for batch 1: 1.79 to 7.330 pg/ml.

Species

Species: Human.

Samples

Sample volume: Serum, plasma: 25 μl, cell culture supernatant: 50 μlitres.

Conservation

Storage: 1 vial of capture microbeads (50 X) 1 vial of biotinylated detection antibody (50 X) 2 vials of human standard mixture A - HS (lyophilized) Store at 2°C to 8°C.

Technical specifications

General
BrandInvitrogen
Supplier ref. (Fisher Scientific)15954274
Specifications
Product typeSimplex kit
Quantity96 dosages
SpeciesHuman
CombinabilityCombine (high sensitivity only)
Type of microbeadGM-CSF [44 ]
Sensitivity of the dosageLess than 15%
Dose rangeAs determined for Lot 1: 1.79 to 7.330 pg/ml
FormatHigh Sensitivity Simplex Kit
For use with (equipment)Luminex™ Instruments
Expressioncolony stimulation factor 2
Gene aliasesGMCSF
Genetic identification (Enter)1437
Gene symbol(s)CSF2
Product rangeProcartaPlex™
ProteinStimulation factor for granulocyte-macrophage colonies
Protein subtypeGM-CSF, colony stimulating factor, CSF, Molgramostine, sargramostim
Type of sampleSerum, plasma, cell culture supernatants (SCC), Plasma, Cell Culture Supernatants
ID UniProtP04141
dimResearchAreaImmunology, Oncology, Neurobiology, Toxicology, Cytokines
Physical characteristics
Volume of sampleSerum, plasma: 25 μl, cell culture supernatant: 50 μlitres
Storage and shipping
Content and storage<ul><li> 1 flacon de microbilles de capture (50 X)</li><li> 1 flacon d’anticorps de détection biotinylé (50 X)</li><li> 2 flacons de mélange étalon humain A - HS (lyophilisé)</li><li>Conservez entre 2°C et 8°C.</li></ul>
Shipping conditionsMoist ice

Origin and customs

Manufacturer ref.EPXS010-10283-901
Country of originAutriche
HS customs code3002 15 00 00
A question or a specific configuration?