Human SIGLEC15(Sialic Acid Binding Ig Like Lectin 15) ELISA Kit – 96 tests

Ref.: BL-RE-950062Manufacturer ref.: ELK0014-96T 96 tests
€513.00 excl. VAT

Human SIGLEC15(Sialic Acid Binding Ig Like Lectin 15) ELISA Kit, 96 tests. For research use only.

Format
96 tests (1 plate of 96 wells)
Species
Human
Target
SIGLEC15 (Sialic Acid Binding Ig Like Lectin 15)
Type of dosage
ELISA sandwich
Sensitivity
0.064 ng/mL
Brand
ELK Biotechnology

Quantitative dosage ELISA human SIGLEC15 sandwich (serum, plasma, saliva, tears), result in 3.5 h.

This ELISA ELK Biotechnology kit allows the quantitative in vitro assay of human SIGLEC15 (Sialic Acid Binding Ig Like Lectin 15) in the following samples: serum, plasma, saliva, tears and other biological fluids.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coated with a specific SIGLEC15 antibody. Standards or samples are added, followed by a biotinylated and peroxidase-coupled (HRP) detection antibody. After adding the TMB substrate and stopping the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 0.064 ng/mL.

Range of dosage

Test range 0.16 to 10 ng/mL (highest standard: 10 ng/mL).

Samples

Serum, plasma, saliva, tears and other biological fluids.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, specific antibodies of human SIGLEC15.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format96 tests (1 plate of 96 wells)
SpeciesHuman
TargetSIGLEC15 (Sialic Acid Binding Ig Like Lectin 15)
Type of dosageELISA sandwich
Performance
Sensitivity0.064 ng/mL
Range of dosage0.16 – 10 ng/mL
Standard (maximum concentration)10 ng/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, saliva, tears and other biological fluids
Research areaAnti-infectious immunity
Alternative namesHsT1361; SIGLEC-15; CD33L3
UniProtQ6ZMC9
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)10.00 ng/mL : DO 2.121; 5.00 ng/mL : DO 1.602; 2.50 ng/mL : DO 1.282; 1.25 ng/mL : DO 0.821; 0.63 ng/mL : DO 0.395; 0.32 ng/mL : DO 0.335; 0.16 ng/mL : DO 0.216; 0.00 ng/mL : DO 0.104
Recovery (doped samples)serum (n=5): 84-97% (average 90%); EDTA plasma (n=5): 95-107% (average 101%); heparin plasma (n=5): 77-95% (average 86%)
Linearity (dilutions)serum (n=5): 1:2 85-94%, 1:4 87-103%, 1:8 97-105%, 1:16 79-90%; EDTA plasma (n=5): 1:2 89-101%, 1:4 85-96%, 1:8 95-104%, 1:16 82-90%; heparin plasma (n=5): 1:2 85-93%, 1:4 87-96%, 1:8 97-105%, 1:16 95-102%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0014-96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 120 μL (storage 4°C or -20°C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 12 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.