EasyStep Human PCT(Procalcitonin) ELISA Kit – 96 tests

Ref.: BL-RE-950134Manufacturer ref.: ELK003ES-96T 96 tests
€625.00 excl. VAT

EasyStep Human PCT(Procalcitonin) ELISA Kit, 96 tests. For research use only.

Format
96 tests (1 plate of 96 wells)
Species
Human
Target
PCT (Procalcitonin)
Type of dosage
ELISA sandwich
Sensitivity
1.5 pg/mL
Brand
ELK Biotechnology

Quantitative ELISA Human PCT Sandwich (Serum, Plasma), result in 1.5 h.

This ELISA EasyStep ELK Biotechnology kit allows in vitro quantitative assays of human PCT (Procalcitonin) in the following samples: serum and plasma. The EasyStep range reduces the protocol to one step of incubation.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific PCT antibody. Standards or samples are added, followed by a detection antibody conjugated with peroxidase (HRP), in one step. After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 1.5 pg/mL.

Range of dosage

The range of the assay is 7.81 to 500 pg/mL (highest standard: 500 pg/mL).

Samples

Serum and plasma.

Rapidity

Result in 1.5 h, protocol in one step.

Specificity

Sandwich format, human PCT specific antibodies.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeEasyStep
Specifications
Format96 tests (1 plate of 96 wells)
SpeciesHuman
TargetPCT (Procalcitonin)
Type of dosageELISA sandwich
Performance
Sensitivity1.5 pg/mL
Range of dosage7.81 – 500 pg/mL
Standard (maximum concentration)500 pg/mL
Duration of dosing1.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum and plasma
Research areaAnti-infectious immunity, hormonal metabolism
Alternative namesPro-Calcitonin
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)500.00 pg/mL : DO 2.558; 250.00 pg/mL : DO 1.476; 125.00 pg/mL : DO 0.853; 62.50 pg/mL : DO 0.558; 31.25 pg/mL : DO 0.324; 15.63 pg/mL : DO 0.218; 7.82 pg/mL : DO 0.174; 0.00 pg/mL : DO 0.080
Recovery (doped samples)serum (n=5): 88-101% (average 93%); EDTA plasma (n=5): 94-103% (average 99%); heparin plasma (n=5): 90-105% (average 98%)
Linearity (dilutions)serum (n=5): 1:2 89-101%, 1:4 85-98%, 1:8 88-99%, 1:16 85-101%; EDTA plasma (n=5): 1:2 95-106%, 1:4 96-108%, 1:8 90-105%, 1:16 86-102%; heparin plasma (n=5): 1:2 91-104%, 1:4 88-102%, 1:8 92-100%, 1:16 89-105 %
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK003ES-96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Microplate of standards: 2 strips × 8 wells (conservation 4 °C or -20 °C)
  • HRP conjugate antibody (100×): 70 μL (storage 4 °C or -20 °C (in the shelter of light))
  • Standard dilution stamp/samples: 24 mL (storage 4 °C or -20 °C)
  • HRP conjugate diluent: 10 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 24 mL (storage 4°C or -20°C)
  • TMB substrate solution: 12 mL (storage 4 °C or -20 °C (in the shelter of light))
  • Stopping solution: 7 mL (storage 4 °C or -20 °C)
  • Plate adhesive films: 2 pieces (storage 4 °C or -20 °C)
  • Instructions for use: 1 (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.