Human Gd-IgA1(Galactose-Deficient IgA1) ELISA Kit – 5 x 96 tests

Ref.: BL-RE-950331Manufacturer ref.: ELK0072-5x96T 5 × 96 tests
€2,659.00 excl. VAT

Human Gd-IgA1(Galactose-Deficient IgA1) ELISA Kit, 5 x 96 tests. For research use only.

Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
Gd-IgA1 (Galactose-Deficient IgA1)
Type of dosage
ELISA sandwich
Sensitivity
5.31 ng/mL
Brand
ELK Biotechnology

Quantitative ELISA human Gd-IgA1 sandwich (serum, plasma, tissue homogenates, cellular lysates), result in 3.5 h.

This ELISA ELK Biotechnology kit allows the quantitative in vitro assay of human Gd-IgA1 (Galactose-Deficient IgA1) in the following samples: serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of Gd-IgA1. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 5.31 ng/mL.

Range of dosage

The range of the assays is 15.63 to 1000 ng/mL (highest standard: 1000 ng/mL).

Samples

Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, specific antibodies of human Gd-IgA1.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format5 × 96 tests (5 plates of 96 wells)
SpeciesHuman
TargetGd-IgA1 (Galactose-Deficient IgA1)
Type of dosageELISA sandwich
Performance
Sensitivity5.31 ng/mL
Range of dosage15.63 – 1000 ng/mL
Standard (maximum concentration)1000 ng/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids
Research areaRenal biomarkers
Alternative namesGd-IgA1
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)1000.00 ng/mL : DO 1.941; 500.00 ng/mL : DO 1.472; 250.00 ng/mL : DO 1.227; 125.00 ng/mL : DO 0.872; 62.50 ng/mL : DO 0.547; 31.25 ng/mL : DO 0.384; 15.63 ng/mL : DO 0.221; 0.00 ng/mL : DO 0.082
Recovery (doped samples)serum (n=5): 85-97% (average 91%); EDTA plasma (n=5): 92-105% (average 98%); heparin plasma (n=5): 82-95% (average 88%)
Linearity (dilutions)serum (n=5): 1:2 90-98%, 1:4 85-92%, 1:8 83-96%, 1:16 93-102%; EDTA plasma (n=5): 1:2 92-105%, 1:4 85-101%, 1:8 85-94%, 1:16 87-96%; heparin plasma (n=5): 1:2 86-97%, 1:4 88-95%, 1:8 92-101%, 1:16 87-98%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0072-5x96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • 5 kits of 96 tests, each containing:
  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 120 μL (storage 4°C or -20°C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 12 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.